marsden M-125 User Manual Download Page 13

 

EMC Guidance and Manufacturer’s Declaration 

Guidance and manufacturer’s declaration - electromagnetic emissions. 
 
The M-545 is intended for use in the electromagnetic environment specified below. The 
customer or user of this scale should assure that it is used in such an environment. 
 

Emission Test 

Compliance 

Electromagnetic environment-
guidance 

RF emissions 
CISPR 11 

Group 1 

This scale uses RF energy only for 
its internal function. Therefore, its 
RF emissions are very low and not 
likely to cause any interference in 
nearby electronic equipment. 

RF emissions 
CISPR 11 

Class B 

This scale is suitable for use in all 
establishments, including domestic 
establishments and those directly 
connected to the public low-
voltage power supply network that 
supplies buildings used for 
domestic purposes. 

Harmonic emissions 
IEC 61000-3-2 

Class A 

Voltage fluctuations/flicker 
emissions 
IEC 61000-3-3 

Compliance 

 

 

Guidance and manufacturer’s declaration – electromagnetic immunity. 
 

The M-545 is intended for use in the electromagnetic environment specified below. The customer or the user 
of this scale should ensure that it is used in such an environment. 
 

Immunity test

 

IEC 60601 test 

level

 

Compliance level

 

Electromagnetic environment-

guidance

 

Electrostatic discharge(ESD)   
IEC 61000-4-2   

± 6 kV contact   
± 8 kV air   

± 6 kV contact   
± 8 kV air 

Floors should be wood, concrete or 
ceramic tile. If floors are covered 
with synthetic material, the relative 
humidity should be at least 30%   

Electrical fast transient/burst 
IEC 61000-4-4   

± 2kV for power 
supply lines + 1kV 
for input/output 
lines   

± 2kV for power 
supply lines Not 
applicable   

Mains power quality should be that 
of a typical commercial or hospital 
environment.   

Surge IEC 61000-4-5   

± 1kV line(s) to 
line(s) ± 2kV line(s) 
to earth   

± 1kV differential 
mode Not 
applicable   

Mains power quality should be that 
of a typical commercial or hospital 
environment.   

 

 
 

 
 

Page 13 

Summary of Contents for M-125

Page 1: ...USER MANUAL M 545 Please take time to read these instructions before starting to use the scale Version 1 0 04 17...

Page 2: ...Symbols 5 Power Supply and Low Battery 6 Installing Batteries 6 Operation Basic Functions 7 Operation Advanced Functions 9 ROHS Compliance 12 EMC Guidance and Manufacturer s Declaration 13 Recommended...

Page 3: ...tion Model Marsden M 545 Accuracy Class Class III Capacity Division 250kg x 100g Weight of Scale Approximately 6kg Units of Measure Kg Function Keys ON ZERO OFF UNIT SEND HOLD BMI TARE BSA Stabilisati...

Page 4: ...away from small children If swallowed promptly seek medical assistance If you have any problems contact Marsden your local dealer your service partner Cleaning We recommend using alcohol based wipes o...

Page 5: ...Taiwan R O C Identification of manufacturer of medical product including address Type B Applied Part Dispose of old appliances separately from your household waste This product must be disposed of at...

Page 6: ...the batteries are installed in the battery box of the indicator Alternatively plug the adaptor 12V 1A into the port on the side of the scale Installing Batteries Remove the battery cover Remove the b...

Page 7: ...cale Press the ON ZERO OFF button firmly When the scale shows 0 0 on the display you are ready to start weighing Switching off the Scale Hold the ON ZERO OFF button for three seconds when the scale is...

Page 8: ...Setting the Scale to Zero If the display shows a reading other than 0 0 when nothing is on the scale it can be reset to zero Press ON ZERO OFF once The scale will return to 0 0 Page 8...

Page 9: ...e patient leaves the scale the weight will remain on the display Press HOLD BMI again to disable the Hold function and return the scale to 0 0 Note If the weight reading remains on the display for mor...

Page 10: ...igit will flash Enter the height by using the TARE BSA button to decrease the value and HOLD BMI button to increase the value To move to the next digit press SEND To confirm the height hold down the O...

Page 11: ...te BMI press TARE BSA and Body Surface Area will be displayed Tare Function Place the item s you wish to deduct from the reading such as a pair of shoes on the scale and press TARE BSA Remove the item...

Page 12: ...he product is capable of being worked on at higher temperatures required by lead free soldering The restricted substances and maximum allowed concentrations in the homogenous material are by weight Su...

Page 13: ...oltage fluctuations flicker emissions IEC 61000 3 3 Compliance Guidance and manufacturer s declaration electromagnetic immunity The M 545 is intended for use in the electromagnetic environment specifi...

Page 14: ...l Guidance and manufacturer s declaration electromagnetic immunity The M 545 is intended for use in the electromagnetic environment specified below The customer or the user of the scale should assure...

Page 15: ...Separation distance according to frequency of transmitter m 150 kHz to 80 MHz d 1 2 P 80 MHz to 800 MHz d 1 2 P 800 MHz to 2 5 GHz d 2 3 P 0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73 1 1 2 1 2 2 3 10 3 8...

Page 16: ...igh Low Zero Count 1 The scale is above its zero range Please remove any weight from the scale and power on again If the scale continues to show the error message it indicates a fault with the electro...

Page 17: ...Notes Page 17...

Page 18: ...Notes Page 18...

Page 19: ...Manufacturer s Declaration of Conformity This product has been manufactured in accordance with the harmonized European standards following the provisions of the below stated directives Page 19...

Page 20: ...ales marsdengroup co uk Manufacturing and Distribution Unit 7 Centurion Business Park Coggin Mill Way Rotherham S60 1FB Head Office Unit 1 Genesis Business Park Sheffield Road Rotherham S60 1DX www ma...

Reviews: