marsden M-110 User Manual Download Page 17

 

EMC Guidance and Manufacturer’s Declaration 

 

Guidance and manufacturer’s declaration-electromagnetic emissions 

The MEDICAL SCALE M-110 is intended for use in the electromagnetic environment specified 

below.  

The customer or the user of the MEDICAL SCALE M-110 should assure that it is used in such an 

environment.  
Emission test   

Compliance   

Electromagnetic environment-guidance 

RF emissions CISPR 11   

Group 1 

The MEDICAL SCALE M-110 uses RF 

energy only for its internal function. 

Therefore, its RF emissions are very low 

and are not likely to cause any 

interference in nearby electronic 

equipment.  

RF emissions CISPR 11   

Class B 

The MEDICAL SCALE M-110 is suitable 

for use in all establishments, including 

domestic establishments and those 

directly connected to the public low-

voltage power supply network that 

supplies buildings used for domestic 

purposes.  

Harmonic emissions IEC 61000-

3-2  

Class A 

Voltage fluctuations /flicker 

emissions IEC 61000-3-3   

Compliance 

 

Guidance and manufacturer’s declaration-electromagnetic immunity 

The MEDICAL SCALE M-110 is intended for use in the electromagnetic environment specified 

below.  

The customer or the user of the MEDICAL SCALE M-110 should assure that it is used in such an 

environment.  

Immunity test 

IEC 60601 test level 

Compliance level 

Electromagnetic environment-

guidance 

Electrostatic 

discharge(ESD)  

IEC 61000-4-2   

± 8 kV contact 

± 2 kV, ± 4 kV, ± 8 

kV, ± 15 kV air 

± 6 kV contact 

± 8 kV air 

Floors should be wood, 

concrete or ceramic tile. If 

floors are covered with 

synthetic material, the relative 

humidity should be at least 

30%  

Electrical fast 

transient/burst IEC 

61000-4-4  

± 2kV for power 

supply lines + 1kV 

for input/output 

lines  

± 2kV for power 

supply lines Not 

applicable  

Mains power quality should 

be that of a typical 

commercial or hospital 

environment.  

Surge IEC 61000-4-

5  

± 1kV line(s) to 

line(s) ± 2kV line(s) 

to earth   

± 1kV differential 

mode Not applicable 

Mains power quality should 

be that of a typical 

commercial or hospital 

environment.  

Page 17

Summary of Contents for M-110

Page 1: ...USER MANUAL M 110 Please take time to read these instructions before starting to use the scale Version 1 2 09 19 Please keep this instruction manual to hand for future reference...

Page 2: ...ry 6 Before Use 7 Operation Basic Functions 8 Operation Advanced Functions 10 Using the Scale with a Printer 14 Using the Scale with Bluetooth 15 Attaching the Height Measure 16 EMC Guidance and Manuf...

Page 3: ...Class Class III Capacity Division 250kg x 100g Weight of Scale Approximately 9kg Units of Measure Kg Function Keys ON OFF HOLD TARE BMI UNIT 0 9 Stabilization Time 1 2 Seconds Operating Temperature 0...

Page 4: ...arsden your local dealer your service partner Cleaning We recommend using alcohol based wipes or similar when cleaning the scale Please do not use corrosive liquids large amounts of water or high pres...

Page 5: ...hong Rd Dali Dist Taichung City 412 Taiwan R O C Identification of manufacturer of medical product including address Electro medical appliance with attachment of type B Dispose of old appliances separ...

Page 6: ...V 2A into the port on the side of the indicator Installing Replacing the Battery Pack 1 Take out the battery housing 2 The rechargeable battery pack will slide into or out of the housing 3 Check that...

Page 7: ...ce 2 Unwind the levelling feet until they make contact with the ground 3 Ensure that all four of the levelling feet and the wheels are firmly on the ground and that the spirit level bubble is located...

Page 8: ...the Scale Press the ON OFF button firmly The scale will first test all of the display segments The scale will now show its current software version number The scale will now go into weighing mode and...

Page 9: ...F button when the scale is turned on The scale will now power down Setting the Scale to Zero If for any reason the scale shows a reading other than 0 0kg it can be reset to zero Press the ZERO key onc...

Page 10: ...once Allow the patient to stand on the scale After a few seconds the scale will lock on the person s weight When the patient leaves the scale the weight will remain on the display Press HOLD again to...

Page 11: ...flashing digit in the height display unless HOLD is pressed Weigh the patient as normal The display will show the weight height and BMI value At this time the weight and height can be freely changed a...

Page 12: ...The left digit on the display will flash Enter the preset tare value by using the numeric keys then press TARE again to confirm the value The display will now show the figure you entered deducted from...

Page 13: ...period to be edited is selected by pressing HOLD E g To input 25 December 2008 8 00 a m Enter the year Press HOLD to confirm and access the date editing field Enter the date E g 12 25 for December 25t...

Page 14: ...I result can be printed Once the person has been weighed and their BMI calculated simply press PRINT to produce the following ticket Connecting the TP 2100 Thermal Printer Plug the cable to the printe...

Page 15: ...sing HOLD select ON enable or OFF disable Press TARE to confirm the setting Note Disabling the Bluetooth function when not in use will reduce battery power consumption Display the bluEt menu Press TAR...

Page 16: ...M5 0 8 9 screws provided mount the two brackets onto the column of the M 110 Using the four M5 0 8 25 screws provided screw the black blocks onto the mounting brackets Using the two M6 1 0 10 screws p...

Page 17: ...Class A Voltage fluctuations flicker emissions IEC 61000 3 3 Compliance Guidance and manufacturer s declaration electromagnetic immunity The MEDICAL SCALE M 110 is intended for use in the electromagne...

Page 18: ...is the a c mains voltage prior to application of the test level Guidance and manufacturer s declaration electromagnetic immunity The MEDICAL SCALE M 110 is intended for use in the electromagnetic env...

Page 19: ...fixed transmitters such as base stations for radio cellular cordless telephones and land mobile radios amateur radio AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with...

Page 20: ...er W Separation distance according to frequency of transmitter m 150 kHz to 80 MHz d 1 2 P 80 MHz to 800 MHz d 1 2 P 800 MHz to 2 7 GHz d 2 3 P 0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73 1 1 2 1 2 2 3 10...

Page 21: ...he scale and try again If the scale continues to show the error message it indicates a fault with the electronics or wiring High Low Zero Count 1 The scale is above its zero range Please remove any we...

Page 22: ...PRODUCT CONFORMITY Harmonised Standards to Which Conformity is Declared EN60601 1 2 EN60601 1 93 42 EEC Medical Devices Directive 2014 31 EU Non Automatic Weighing Instrument Directive Page 22...

Page 23: ...Directive 2014 31 EU Non automatic Weighing Instruments Directive Please see separate document showing on sticker of device for above CE marking Authorized EU Representative DISTRIBUTOR Manufactured b...

Page 24: ...E mail sales marsdengroup co uk Manufacturing and Distribution Unit 7 Centurion Business Park Coggin Mill Way Rotherham S60 1FB Head Office Unit 1 Genesis Business Park Sheffield Road Rotherham S60 1...

Reviews: