Trawl Explorer | V5 | System Configuration and Display
7
Helps you detecting targets on the echogram. Corresponds to
Channel minimum TS
in
Mosa2.
8
Do not change this setting.
Click
Apply
when you have finished.
Results
The sensor is added to the system. You should see incoming data from the control panels, in
Sensors Data
. You can now configure the display of incoming data in Scala/Scala2.
Configuring the Sensor Display on Scala/Scala2
You can display Trawl Explorer measurements (e.g. echogram, depth, temperature,...) on pages in
Scala/Scala2. For V3 version of the sensor, you can also display target strength data, that help you
identify fish.
About this task
Trawl Explorer measurements are displayed in the control panels, under
Sensors Data
/
Mx
. Data title should be
Trawl Explorer
followed by the node where the Trawl Explorer was
placed when added to the system. Data displayed (e.g. depth, temperature, pitch & roll) depend on
the firmware installed.
Procedure
1.
From the top left corner of the screen, click
Menu
>
Customize
and enter the password
eureka
.
2.
Go to the control panels, then from
Sensors Data
/
Mx
, click + hold Trawl
Explorer data (for example Depth) for 3 seconds until a rectangle appears and drag it to a page
in the middle of the screen.
|
48