Copyright by Servizio Clienti ANGELO PO Spa
89
4.4. Gas Test
4.4.1.
Setup gas (level 3)
To ensure that the gas system functions correctly safely, the user is required to install the
equipment performing the following test wizard:
1. Prepare the flue gas analyzer and place a magnet in
correspondence of the door micro-switch, allowing the
procedure to be carried out with the door open. (see
paragraph 4.6).
Take care to avoid burns or injuries.
2. Enter Service menu (Password:
SAAP
) and choose “setup gas” (Password:
SI74
).
3. On the next screen check that the type of gas is set to G20,
if you use a different gas from the pulldown menu select the
gas used (see section 4.9 Change of Gas).
4. To start the wizard, select "Burner 1. (For models FX201G3
and FX202G3 perform first the procedure on the burner 1
and thereafter on the burner 2).
Summary of Contents for ANGELO PO COMBISTAR FX
Page 1: ...1 Rev 0 ...
Page 6: ...Copyright by Servizio Clienti ANGELO PO Spa 6 1 COMMERCIAL MODEL NUMBER ...
Page 7: ...Copyright by Servizio Clienti ANGELO PO Spa 7 FX Models table ...
Page 10: ...Copyright by Servizio Clienti ANGELO PO Spa 10 OVEN CONNECTION DIAGRAM FX 61 G3 ...
Page 19: ...Copyright by Servizio Clienti ANGELO PO Spa 19 2 4 Steam producing operation injectors code ...
Page 21: ...Copyright by Servizio Clienti ANGELO PO Spa 21 ...
Page 44: ...Copyright by Servizio Clienti ANGELO PO Spa 44 ...
Page 46: ...Copyright by Servizio Clienti ANGELO PO Spa 46 Fuses on Power Board ...
Page 61: ...Copyright by Servizio Clienti ANGELO PO Spa 61 ...
Page 67: ...Copyright by Servizio Clienti ANGELO PO Spa 67 Functional diagram gas system ...
Page 104: ...Copyright by Servizio Clienti ANGELO PO Spa 104 ...
Page 151: ...Copyright by Servizio Clienti ANGELO PO Spa 151 PICTURE 7 PICTURE 8 PICTURE 5 PICTURE 6 ...
Page 162: ...Copyright by Servizio Clienti ANGELO PO Spa 162 6 15 Roll In adjustment RX201 RX202 ...
Page 163: ...Copyright by Servizio Clienti ANGELO PO Spa 163 ...