4.2.5.
Combustion control board
NOTES:
-
During the installation,
it’s necessary to
respect the correct connection of phase
and
neutral
(not
inverted).
If
the
connection is inverted the microAmpere
reading of the flame detector will be lower
as it should be.
-
On the level 3 models the microAmpere
reading can be displayable. This function
you can activate from the Service menu;
the reading needs to be divided by 10
(e.g. 57 / 10 = 5,7 microAmpere).