4.1. System operation
4.1.1.
Premixed system general principles
FX oven gas system is a "total premix", this means that the gas is completely mixed with
the necessary air to have "good" combustion and then the air-gas mixture is ignited at the
burner.
Therefore, the relationship between the quantity of air and the amount of mixed gas is
constant and must be properly adjusted to avoid being too rich (risk of production of CO)
or too poor (unstable flames).
In the diagram below we highlight the major differences between the blown system (FM)
and premixed system (FX): In the blown system, the gas and air inlet circuit to the burner
are separated, while in the premixed system both flow into the mixer before going into the
burner.
Consequently, in the blown system to adjust the gas flow and the combustion quality it is
enough to adjust the gas valve output pressure or replace the nozzle.
In the premixed system, however, the gas valve output pressure is zero because of the
vacuum created by the fan and therefore, only at low speeds (when the influence of the
blower decreases), the combustion is controlled by the gas valve offset. To make this
adjustment it is necessary to use a gas flue analyzer.
Furthermore, an electronic variable-speed blower, controlled by the power board, allows
you to change the quantity of the air-gas mixture.
Summary of Contents for ANGELO PO COMBISTAR FX
Page 1: ...1 Rev 0 ...
Page 6: ...Copyright by Servizio Clienti ANGELO PO Spa 6 1 COMMERCIAL MODEL NUMBER ...
Page 7: ...Copyright by Servizio Clienti ANGELO PO Spa 7 FX Models table ...
Page 10: ...Copyright by Servizio Clienti ANGELO PO Spa 10 OVEN CONNECTION DIAGRAM FX 61 G3 ...
Page 19: ...Copyright by Servizio Clienti ANGELO PO Spa 19 2 4 Steam producing operation injectors code ...
Page 21: ...Copyright by Servizio Clienti ANGELO PO Spa 21 ...
Page 44: ...Copyright by Servizio Clienti ANGELO PO Spa 44 ...
Page 46: ...Copyright by Servizio Clienti ANGELO PO Spa 46 Fuses on Power Board ...
Page 61: ...Copyright by Servizio Clienti ANGELO PO Spa 61 ...
Page 67: ...Copyright by Servizio Clienti ANGELO PO Spa 67 Functional diagram gas system ...
Page 104: ...Copyright by Servizio Clienti ANGELO PO Spa 104 ...
Page 151: ...Copyright by Servizio Clienti ANGELO PO Spa 151 PICTURE 7 PICTURE 8 PICTURE 5 PICTURE 6 ...
Page 162: ...Copyright by Servizio Clienti ANGELO PO Spa 162 6 15 Roll In adjustment RX201 RX202 ...