4.8. Gas alarms
GAS alarm table
Alarm Code
PROBLEM
SOLUTION
1
E12:F4
The blower fan is working but there is no ignition
spark
1. Check the wirings on the igniter and on
the spark plug.
2. Check the continuity of the HF cable.
3. Check the spark plug ground
connection
4. Dismantle the spark plug and check
the electrodes.
5. Check the power supply to the igniter.
6. Replace the igniter.
The blower fan is working and the spark is good
but there is no flame ignition.
1. Check the inlet gas pressure.
2. Check gas nozzle
3. Increase gas pressure regulation
(PR.ADJ.) until the burner ignition. (see
section 4.4.4.1)
4. Check gas pipe fixing
5. Check gas valve power supply
6. Check that the outlet pressure of the
gas is free
7. Clean the blower fan air intake
Detonation at the ignition
1. Dismantle and check the spark plug.
2. Check combustion and gas
parameters.
The flame is lighting but after some seconds the
flame goes off.
1. verify the flame detector cable
2. verify the correct power connection
(see chapter 4.2.5.)
3. replace the flame detector and/or the
combustion control
2
E12:F5
Flame signal missing during the working
1. Check the flame sensor
2. verify the correct power connection
(see chapter 4.2.5.)
3
E12:F6
Overheating combustion control board
Check that the cooling fans in the components
compartment are working properly. Check and
cleaning air vents under the dashboard and
below the components compartment.
Summary of Contents for ANGELO PO COMBISTAR FX
Page 1: ...1 Rev 0 ...
Page 6: ...Copyright by Servizio Clienti ANGELO PO Spa 6 1 COMMERCIAL MODEL NUMBER ...
Page 7: ...Copyright by Servizio Clienti ANGELO PO Spa 7 FX Models table ...
Page 10: ...Copyright by Servizio Clienti ANGELO PO Spa 10 OVEN CONNECTION DIAGRAM FX 61 G3 ...
Page 19: ...Copyright by Servizio Clienti ANGELO PO Spa 19 2 4 Steam producing operation injectors code ...
Page 21: ...Copyright by Servizio Clienti ANGELO PO Spa 21 ...
Page 44: ...Copyright by Servizio Clienti ANGELO PO Spa 44 ...
Page 46: ...Copyright by Servizio Clienti ANGELO PO Spa 46 Fuses on Power Board ...
Page 61: ...Copyright by Servizio Clienti ANGELO PO Spa 61 ...
Page 67: ...Copyright by Servizio Clienti ANGELO PO Spa 67 Functional diagram gas system ...
Page 104: ...Copyright by Servizio Clienti ANGELO PO Spa 104 ...
Page 151: ...Copyright by Servizio Clienti ANGELO PO Spa 151 PICTURE 7 PICTURE 8 PICTURE 5 PICTURE 6 ...
Page 162: ...Copyright by Servizio Clienti ANGELO PO Spa 162 6 15 Roll In adjustment RX201 RX202 ...
Page 163: ...Copyright by Servizio Clienti ANGELO PO Spa 163 ...