Page 1: ...MS9470 MS9770 MS9970 MARMITEK NICOSHOP MS9470 MS9770 MS9970 SECURITY AND HOME AUTOMATION SYSTEM...

Page 2: ...alling the system for you you have to read this manual carefully as it contains important information regarding operation and use of the Marmitek SC2800 In case of any problems during installation or...

Page 3: ...ways carefully follow the instructions in the users guide 2 SAFETY PRECAUTIONS There is a hazard of electrical shock or injury if the system the PS500 in particular is installed in any other way than...

Page 4: ...ON MATERIALS NOT INCLUDED 3 2 IMPORTANT FEATURES Up to 16 wireless sensors can be installed on the base station Alarm and system messages can be sent to up to 4 different phone numbers Anti jamming ci...

Page 5: ...whereby a message containing an address consisting of a so called house and unit code and an instruction e g on or off are transmitted to e g a lamp module These signals are transmitted over all mains...

Page 6: ...replaced POWER Indication for proper operation of the PS500 Lights during normal operation 7 KEYBOARD To program and operate the security system 8 UNIT ON UNIT OFF For operating Marmitek X 10 Home Aut...

Page 7: ...tabletop use or vertically wall mounted INSTALLATION Choose a suitable place for the base station close to a power outlet 230VAC and a telephone socket For maximising the range it is recommended to p...

Page 8: ...itioned without running the risk of obstructing or damaging the sensor when opening this door or window Position the sensor if possible as high up as possible This will result in the best possible ran...

Page 9: ...reported to the base station after 30 seconds It may seem that the motion sensor is not functioning properly however every motion detected at any time always creates an alarm The advantage of this me...

Page 10: ...the ARM key for more than 3 seconds and release the button the indicator blinks 10 MARMITEK 1 2 3 4 7 9 5 8 4 5 KR21 KEY CHAIN REMOTE CONTROLS 4 6 SYSTEM REMOTE CONTROL SH624 OPTIONAL FOR MS9470 CONTR...

Page 11: ...ation all code switches of the system components have to set to the same House Code 7 TEXT WINDOW On the piece of paper behind the plastic cover of the text window you can note which Home Automation m...

Page 12: ...circumstances You now can e g still protect a door or window out of the radio range of base station by using a wired magnetic contact You can now also use third party non Marmitek sensors in combinat...

Page 13: ...up 1 Inserting the batteries Open the battery compartment at the front Insert the 2 batteries observing the polarity indicated in the unit Close the battery compartment Note The code settings are main...

Page 14: ...the SC2800 base station you can enter a temperature setback between 1 and 9 degrees When the Maxi Controller is in Disarm or Arm home mode it will turn On or Off the X10 module connected to the boiler...

Page 15: ...utton of sensor 2 Indicator of next available free zone comes on REPEAT THIS PROCESS UP TO A MAXIMUM OF 16 SENSORS THE ZONES ARE GOING TO BE OCCUPIED ONE BY ONE Reset the mode switch to RUN 1 or RUN 2...

Page 16: ...curity system without the siren only telephone dialler and lights In case of a break in the siren built into the base station will not be activated N B Extra external sirens will always be activated T...

Page 17: ...re not allowed to use emergency numbers of e g police unless you are authorised to do so Every time you press a key you hear a short confirmation beep 1 Set the mode switch to the INSTALL position All...

Page 18: ...mode switch to the INSTALL position All indicators of occupied zones come on 2 Key in your 4 digit PIN code factory default 0000 refer to 5 8 3 Press RECORD RECORD indicator will come on and remain o...

Page 19: ...to 5 8 3 Press key number 5 4 Press ENTER 5 Press 0 for instantaneous alarm or Press 1 for delayed alarm 6 Reset the mode switch to the RUN 1 or RUN 2 position Zone indicators go out OVERVIEW DELAY TI...

Page 20: ...on as long as the interfering signal is detected A fixed 4 language warning message will be transmitted to the 4 telephone numbers programmed into the base station Even if the interfering signal disap...

Page 21: ...have to contact your Marmitek Authorised Service Centre MASC to reset the access code to the factory default 0000 Entering you PIN code Every time you press a key you hear a short confirmation beep 1...

Page 22: ...ors go out If necessary a sensor can be erased from the memory of the base station e g code changed when batteries were changed When you want to re register a specific sensor with the same zone you ha...

Page 23: ...When the system is armed after one minute ARM indicator comes on Press the ARM AWAY button on the SH624 system remote control Depending on the settings of the SC2800 5 6 the system will arm instantane...

Page 24: ...times until somebody confirms the call by pressing a 0 Home Automation modules When an alarm is detected all lights connected to the lamp module LM12 LW10 and LD10 will switch on and off flash during...

Page 25: ...tone confirmation ARM indicator goes out or flashes when an alarm was detected previously 6 4 DISARMING THE SYSTEM You disarm the system in the same way as described under 6 4 Base station The ARM in...

Page 26: ...rol Press the 2 red PANIC buttons simultaneously The panic alarm will be activated without any delay Depending on the SC2800 settings the siren will sound or not refer to 5 3 The zone indicator panel...

Page 27: ...UCI E DEGLI ELETTRODOMESTICI 6 8 1 FUNZIONI DISPONIBILI PER LA DOMOTICA Indirizzo di riferimento A1 del Maxi Controller SC2800 1 LUCE ALLARME Un Modulo settato su A1 viene acceso durante il periodo Ar...

Page 28: ...quindi installare sirene aggiuntive settate sull indirizzo B5 senza bisogno di stendere cavi aggiuntivi MODULO MARMITEK X 10 SETTATO SU B5 7 OFF AWAY Il Modulo settato su B6 viene spento quando il si...

Page 29: ...olta che si preme un tasto si sentir un beep di breve durata 1 Impostare l interruttore Mode su INSTALL si accendono tutti gli indicatori delle zone 2 Inserire il codice PIN a 4 cifre default 0000 3 P...

Page 30: ...2 position Zone indicators go out 2 ARMING AND DISARMING VIA THE TELEPHONE As soon as the base station answers your call you can arm or disarm the security system Arming and disarming the system 1 Cal...

Page 31: ...e same dialling procedure as a real alarm message i e dials the same phone numbers 1 Set mode switch to INSTALL All indicators of occupied zones come on 2 Enter your 4 digit PIN code factory default 0...

Page 32: ...erly closed When everything is OK now arm the system again As long as you hear the dual tone signal you can press BYPASS to ignore the problem zone the zone indicator starts flashing rapidly The arm t...

Page 33: ...r remove the batteries and press the TEST button Reposition the batteries and press the TEST button for 3 seconds Set the mode switch of the base station to INSTALL and register the sensor by pressing...

Page 34: ...hat the equipment specified below complies with the essential requirements of this Directive The MS9470 MS9770 MS9970 Protector Xtra complies to standards EN 60 950 1992 A1 A2 1993 A3 1995 A4 A11 1997...