background image

USER MANUAL

LMM22

20440/20120228 • LMM22

ALL RIGHTS RESERVED MARMITEK ©

LMM22

Dimmer Micromodule, 2 load

Summary of Contents for LMM22

Page 1: ...USER MANUAL LMM22 20440 20120228 LMM22 ALL RIGHTS RESERVED MARMITEK LMM22 Dimmer Micromodule 2 load...

Page 2: ......

Page 3: ...ENTS 2 SAFETY WARNINGS 3 HOW DOES MARMITEK X 10 WORK 4 ADRESSES 4 SIGNAL RANGE 5 TWO LOAD DIMMER MICRO MODULE 7 FUNCTIONS 7 INSTALLATION 9 PROGRAMMING 10 FREQENTLY ASKED QUESTIONS 11 TECHNICAL DATA 13...

Page 4: ...light sources x In case of improper usage or if you have altered and repaired the product yourself all guarantees expire Marmitek does not accept responsibility in the case of improper usage of the p...

Page 5: ...Modules 3 Transmitters Wireless components like remotes The signals of these components will be received by a controller with transceiver functionality IRRF 7243 TM13 CM15Pro The Transceiver will tran...

Page 6: ...d over more than one phase more than one group is no problem For bigger buildings or longer distances we advice you to use an active repeater instead of passive FD10 s 2 It is possible that Marmitek X...

Page 7: ...rces than your Marmitek X 10 Controllers However it is possible that the Marmitek X 10 signals are disturbed by e g baby phones which are in TALK mode continuous transmission When these kind of signal...

Page 8: ...ontrol On Off and Dim x Suitable for 230V and Eco halogen lighting x Remote control via the mains using Marmitek X 10 Commands and with one or more momentary switches x Can be used in combination with...

Page 9: ...MARMITEK 8 controlling low energy light bulbs and tube lighting An Appliance module should be used for these devices x Control Load QTY Two...

Page 10: ...tandard rocker switch x Connect the thin Black Green and Yellow wires of the built in module to the double 1 way momentary switches normally open contacts x Position the MicroModule against the back w...

Page 11: ...ule needs to be set to the program mode Press and hold the Program button for 5 seconds indicator light flickers once the controlled light Turns ON means entering Program mode Then you transmit the ad...

Page 12: ...t your incoming mains My modules will not respond to my controller Make sure that the House Code on all Modules and Controllers are set to the same House Code A P My modules will not react to my remot...

Page 13: ...nt signals to be disturbed when more than one transceiver is transmitting The Transceivers will wait for a quite power line before transmitting their data To prevent your Marmitek X 10 System to becom...

Page 14: ...ights On On Off DIM BRIGHT Extended Dim Input switch 1 way standard rocker switch 1 way momentary switch normally open contact Use in 3 phase installation FD10 3x or FKX40 necessary Connections Wire f...

Page 15: ...gular household waste streams It is your responsibility to dispose of this and other electric and electronic equipment via designated collection facilities appointed by the government or local authori...

Page 16: ...imation of the laws of the Member States relating to electromagnetic compatibility Directive 2006 95 EC of the European Parliament and of the Council of 12 December 2006 on the harmonisation of the la...

Page 17: ...tent including but not limited to model numbers software audio video text and photographs rests with Marmitek B V Any use of the Content but without limitation distribution reproduction modification d...

Page 18: ...LMM32 17...

Page 19: ...MARMITEK 18...

Page 20: ......

Reviews: