Markilux Syncra uno Mounting Instructions Download Page 1

 

 

markilux Awnings 

 

Handover declaration 

To be passed on to the users of folding-arm awnings 

 

 

0

6

/0

4

/0

9

 

 

Wind resistance class 0 

Wind resistance class 1 

Wind resistance class 2 

Wind resistance class 3 

 

 

 

 

The Wind Resistance Class 0 
represents either a 
performance not required or 
not measured or a product, 
which does not fulfill the 
requirements of class 1. 

The awning may remain extended 
up to maximum Wind Force 4. 

The awning may remain 
extended up to maximum Wind 
Force 5. 

At Wind Force 6 the awning 
must be retracted! 

 

Definition according to Beaufort:  
Moderate breeze, moderate wind 
Wind moves branches and thinner 
boughs, raises dust and loose 
paper. 

Definition according to Beaufort:  
Fresh breeze, fresh wind 
Small deciduous trees begin to 
sway, white foam caps form at 
sea. 

Definition according to 
Beaufort:  
Strong wind 
Heavy boughs sway, umbrellas 
are difficult to hold, telephone 
lines whistle in the wind. 

The awning may not be used 
during wind. 

Speed 20-27 km/h = 5.5-7.4 m/s 

Speed 28-37 km/h = 7.5-10.4 
m/s 

Speed 38-48 km/h = 10.5-13.4 
m/s 

Source: German Meteorological Service (DWD) – Offenbach, Wind Forces in Beaufort

 

 

The user has been properly instructed in the operation of the awning: 

 

yes 

 

no

 

The user has been handed the following documentation: 

 

 

Operating instructions 

 

yes

 

 

no

 

 

 

Installation and setting instructions 

 

yes

 

 

no

 

 

 

of the motor, switch and controller manufacturers, if available 

The awning may be used under the following conditions: 

Wind:   

permitted

 

up to Wind Resistance Class

 

 

= Wind force 

 

 

 

permitted

 

with awning extended completely

 

Rain: 

 

 

not permitted

 

at a pitch angle below 25% = 14°, measured from the horizontal

 

Danger of frost and snow: 

not permitted 

 
 
Date

:   

 

Signature of installation engineer:   

 

 

 

 

 
 

Signature of user*: 

 

 

 

 

 

 

The  European  standard  DIN  EN  13561  establishes  the  requirements  for  the 
construction  and  fastening  of  awnings.  The  construction  of  this  markilux  awning
fulfills the requirements of the Wind Resistance Class 2 specified in the CE mark of 
conformity. The wind resistance class describes the wind speed, at which an awning 
may  be  used.  If  used  above  the  approved  wind  speed,  considerable  dangers  can 
occur  in  rain  and  in  snow,  the  awning  can  be  destroyed  or  collapse.  Which  wind 
resistance  class  the  installation  achieves,  critically  depends  on  the  type  and  the 
number of fastening materials as well as on the existing fastening background. 
 
The  awning  may  only  be  used  up  to  the  wind  resistance  class  declared  by  the 
installation firm.  This  can  differ  from  the  wind  resistance  class  specified  above  in 
the CE-mark of conformity.  
In  full  knowledge  of  the  local  conditions  and  after  completed  installation,  the 
installation firm declares to the user, whether the wind resistance class specified by 
markilux  has  been  achieved  in  the  installed  state  and  documents  the  actual  wind 
resistance class achieved. 
Automatic controllers are to be adjusted to the declared wind resistance class. 

*  

Confirmation with the signature, of having received a duplicate of the handover declaration! 

 

 

markilux 

Schmitz-Werke GmbH & Co. 

KG 

Hansestraße 87 

D-48282 Emsdetten 

 

DIN EN 13561  

Awnings for use on the 

outside of buildings 

 

Wind resistance class 2 

Summary of Contents for Syncra uno

Page 1: ...sistance Class Wind force permitted with awning extended completely Rain not permitted at a pitch angle below 25 14 measured from the horizontal Danger of frost and snow X not permitted Date Signature of installation engineer Signature of user The European standard DIN EN 13561 establishes the requirements for the construction and fastening of awnings The construction of this markilux awning fulfi...

Page 2: ...sistance Class Wind force permitted with awning extended completely Rain not permitted at a pitch angle below 25 14 measured from the horizontal Danger of frost and snow X not permitted Date Signature of installation engineer Signature of user The European standard DIN EN 13561 establishes the requirements for the construction and fastening of awnings The construction of this markilux awning fulfi...

Page 3: ... markilux 6000 5010 1500 1550 skylife 2 1200 990 Page 7 5 Assembly of the posts Page 8 6 1 Installation of the transverse brace syncra uno with markilux 6000 5010 3300 3300 pur 1500 1550 skylife 2 1200 Page 9 6 2 Installation of the transverse brace syncra uno with markilux 990 Page 9 7 Hanging up the awnings Page 10 8 Mount frontal covering elements syncra uno with markilux 6000 5010 1500 1550 sk...

Page 4: ... width of the unit M awning width H projection AH unit height DH headroom SAM central posts spacing dimensions in cm HBH Raised edge stone holder HB on site weight ing via two raised edge stones per side DIN 483 Form A A4 width 15 cm height 30 cm length 100 cm weight 100 kg piece ...

Page 5: ...ux 6000 markilux 5010 markilux 3300 3300 pur AH 296 cm 294 cm 298 cm SAM M 18 cm M 20 cm M 11 cm Overall width M M M 3 cm markilux syncra uno with markilux 1500 1550 skylife 2 markilux 1200 markilux 990 AH 300 cm 299 cm 295 cm SAM M 11 cm M 11 cm M 46 cm Overall width M 3 cm M 3 cm M ...

Page 6: ... mm The distance upper edge bracket 5 to upper edge cross beam 1 is 12 mm syncra uno with markilux 5010 DHH 6 mm 1 Cross beam 2 Roof bracket 3 Washer Ø 10 5 4 Hexagonal head screw M 10 x 100 5 Bracket 6 Washer Ø 13 7 Hexagonal head screw M 12 x 120 8 Hexagonal head screw M 12 x 120 9 Hexagonal nut M 10 10 Hexagonal nut M 12 Dimensions in mm ...

Page 7: ... DHH 54 mm markilux 1200 DHH 45 mm syncra uno with markilux 990 markilux 990 DHH 7 mm 1 Cross beam 2 Roof bracket 3 Washer Ø 10 5 4 Hexagonal head screw M 10 x 100 5 Bracket 6 Washer Ø 13 7 Hexagonal head screw M 12 x 120 9 Hexagonal nut M 10 10 Hexagonal nut M 12 Dimensions in mm ...

Page 8: ...on dependent syncra uno with markilux 3300 3300 pur Bracket 200 mm 1 Cross beam 6 Washer Ø 13 8 Hexagonal head screw M 12 x 130 10 Hexagonal nut M 12 16 Spacer plate 60 width 17 Spacer plate 100 width 18 Bracket 60 width 19 Bracket 100 width 20 Bracket 200 width Dimensions in mm ...

Page 9: ...ments 4 arrange the spacing and align 3 Mark the positions of the roof brackets 3 on the upper part of the roof elements 4 each time Drill through the plates and brackets from above Ø 4 2 mm 4 Mark the roof elements 4 for later assembly and remove again For syncra with markilux 1500 1550 additional brush seals 6 are glued under the roof elements 1 Square plug 2 Cross beam 3 Roof bracket 4 Roof ele...

Page 10: ... 2 Post 3 Circular tube 4 Hexagonal nut M 10 5 Washer Ø 10 5 6 Hexagonal head screw M 10 x 130 7 Hexagonal head screw M 10 x 120 Dimensions in mm 2 Erect the post and hang up the 4 raised edge stone holders 9 in the adjustable foot 1 3 Lay the raised edge stones 10 in the brackets 9 1 Adjustable foot 9 Raised edge stone holder 10 Raised edge stone 4 Check the posts alignment and the clearance SAM ...

Page 11: ...hexagonal head screws 7 1 Cross beam 6 Post 7 Hexagonal head screw M 16 x 120 8 Hexagonal nut M 16 9 Washer Ø 17 Dimensions in mm 6 2 Installation of the transverse brace syncra uno with markilux 990 Dimensions in mm Lower the transverse brace 1 onto the posts 2 or 6 upper brackets the brackets 10 lie externally The distance of the transverse brace s 1 outer surface from the middle of the post sho...

Page 12: ...vering element 9 brackets 10 underneath the roof elements 4 and screw to the square plugs 1 with the screws included 7 2 Mark the position of the brackets on the roof ele ment bore through from above Ø 4 2 mm and screw with the screws 8 included 3 Lay the coverboard additional profiles 6 align mark at brackets 10 and the roof elements 4 and drill Ø 4 2 mm Screw with the slotted pan head screws 6 4...

Page 13: ...otted pan head screws 6 4 8 x 13 The distance of the drilled holes at the casing 2 should amount to be tween min 300 mm and max 700 mm 5 Lay the coverboard additional profiles 7 align mark to brackets 12 and rafters 9 and drill Ø 4 2 mm Screw with the slotted pan head screws 6 4 8 x 13 6 Pull the sealing profile 8 into the coverboard addi tional profiles 7 1 Slotted pan head screw 4 8 x 9 5 2 Late...