background image

 

 

4

 

 

 

 

INSTALLATION 

 

Manual Shut-Off Valve: 

This  installer-supplied  valve  must  be  installed  in  the  gas  service  line  ahead  of  the  appliance  and 
regulator in the gas stream and in a position accessible in the event of an emergency. 

Pressure Regulator: 

Gas pressure regulator provided with the equipment must be installed when the appliance is connected 
to gas supply. 
 
All commercial cooking equipment must have a pressure regulator on the incoming service line for safe 
and efficient operation, since service pressure may fluctuate with local demand. The pressure regulator 
comes with the oven. Failure to install the pressure regulator will void the equipment warranty! 
 
The regulators supplied with MARKET FORGE INDUSTRIES, INC. Ovens, have 3/4” inlet /outlet openings 
and  are  adjusted  at  the  factory  for  5”  WC  (Natural  gas)  or  10”  WC  (Propane  gas)  depending  on 
customer’s ordering instructions. 
 
Prior  to  connecting  the  regulator,  check  the  incoming  line  pressure,  as  these  regulators  can  only 
withstand a maximum pressure of ½ PSI (14”WC). If the line pressure is beyond this limit, a step-down 
regulator  will  be  required.  The  arrow  shown  on  the  bottom  of  the  regulator  body  shows  gas  flow 
direction; it should point downstream to the appliance. The red air vent cap on the top regulator is part 
of the regulator and should not be removed. 
  
Any  adjustments  to  regulators  must  be  made  only  by  qualified  service  personnel  with  the  proper 
equipment.  

Connections: 

Please check installer-supplied intake pipes visually and /or blow them out with compressed air to clear 
any  dirt  particles,  threading  chips,  or  other  foreign  matter  before  installing  a  service  line.  When  gas 
pressure  is  applied  these  particles  can  clog  orifices.    All  connections  must  be  sealed  with  a  joint 
compound suitable  for LP gas, and all connections must  be tested with a soapy water  solution before 
lighting any pilots! 

Flexible Coupling, Connectors and Casters: 

For  an  appliance  equipped  with casters  the  installation  shall  be  made  with  a  connector that  complies 
with the Standard for Connectors for Movable Gas Appliances, ANSI Z21.69 or Connectors for Moveable 
Gas  Appliances,  CAN/CGA-6.16,  and  a  quick  –disconnect  device  that  complies  with  the  standard  for 
Quick Disconnect Devices for Use with Gas Fuel, ANSI Z21.41, or Quick Disconnect Devices for Use with 
Gas Fuel, CANI-6.9. Adequate means must be provided to limit the movement of the appliance without 
depending  on  the  connector  and  the  quick-disconnect  device  or  its  associated  piping  to  limit  the 
appliance movement.  Restraining devices may be attached to the back frame/panel of the unit. 
 
If legs or casters are not used, the unit must extend 2” beyond the front edge of a noncombustible curb 
or platform.  Broilers are for installation in non-combustible locations only. 
 

Before lighting, check all joints in the gas supply line for leaks.

 

Summary of Contents for 2-HPGR

Page 1: ...QUIPMENT FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE Form Number S 6109 09 13 Printed in USA 35 Garvey Street Everett MA 02149 Telephone 617 387 4100 866 698 3188 Fax 617 387 4456 800 227 2659 custserv mfii com www mfii com CAUTION INSTRICTIONS TO BE FOLLOWED IN THE EVENT THE USER SMELLS GAS SHALL BE POSTED IN A P...

Page 2: ...n 3 Dimensions 3 INSTALLATION Manual Shut Off Valve 4 Pressure Regulator 4 Connections 4 Flexible Coupling Connectors and Casters 4 Check for Gas Leaks 5 Disclaimer 5 MAINTENANCE Daily Cleaning 6 Periodic Cleaning 6 Cleaning Stainless Steel 6 ILLUSTRATED PARTS Exploded View 7 Complete 2 HPGR Parts List 8 ...

Page 3: ...ovable ring type and shall be provided with a removable drip pan Controls are recessed in the front of the burners for ease of operation and cleaning Countertop and cabinet base shall be constructed of polished 16 gauge stainless steel and designed to match other Market Forge equipment Cabinet base is equipped with a hinged door with magnetic latch The 2 burner hot plate shall be equipped with as ...

Page 4: ...e elevation exceeds 2000 609 6 meters above sea level specify installation altitude so that proper orifices can be provided Gas Connection 60 000 Total BTU Natural Gas Propane Gas LP 3 4 NPT 19mm on the right hand rear of the appliance The pressure regulator supplied is to be connected here by the installer Manifold gas pressure from regulator to gas valve shall be 5 W C for natural and 10 W C for...

Page 5: ... Any adjustments to regulators must be made only by qualified service personnel with the proper equipment Connections Please check installer supplied intake pipes visually and or blow them out with compressed air to clear any dirt particles threading chips or other foreign matter before installing a service line When gas pressure is applied these particles can clog orifices All connections must be...

Page 6: ...etting and the burner should light 5 Check the burner orifice elbow connection downstream of the valve with a soapy water solution 6 Check the burner visually for blue flame There should be no yellow tips or soot If yellow tipping occurs call an authorized service person to adjust the burner air shutter Disclaimer All MARKET FORGE INDUSTRIES INC appliances are adjusted and tested before leaving th...

Page 7: ...ke sure the ports are not clogged Check valves and lubricate if necessary Consult your service agency or local Gas Company Cleaning Stainless Steel All stainless steel body parts should be wiped regularly with hot soapy water during the day and with a liquid cleaner designed for this material at the end of each day DO NOT USE steel wool abrasive cloths cleaners or powders to clean stainless surfac...

Page 8: ...7 ILLUSTRATED PARTS ...

Page 9: ...f tubing 12 93 5174 3 16 Aluminum Tubing Specify length of tubing 13 93 5121 Safety Valve 14 93 5171 Safety Valve Bracket PN 2174 15 93 5203 Orifice Elbow 3 8 CC X 3 8 27 Brass 16 93 5226 Bracket for Orifice Elbow 17 93 5158 Orifice Hood 39 Brass Natural Gas 30 000 B T U 17 93 5355 52 Orifice LPG 18 93 5253 Knob Flat Side Down BLACK 19 93 5263 Valve Cover W Logo 20 93 5264 Top Back Spacer 21 93 52...