Market Central 6100924-SC Instruction Manual Download Page 1

         

Market Central

  

 

          www.secureswitch.com

 

 

 

 
 

February,  2011

 

 
 

Fiber Optic Network  

Access Control A/B Switch

 

 

Part Numbers 

 

6100924-SC    1U Rackmount, Single 

FONAC A/B Switch,  

with SC connectors

 

 
 
 
 

 

 
 
 
 

Rackmount 

 
 
 
 
 
 

 
 
 
 
 
 
Market Central Inc., 500 Business Center Drive, Pittsburgh, PA 15205 
Phone: (412) 494-2800, Fax: (412) 494-5550, 

www.secureswitch.com

  CAGE Code 1BGJ7 

Copyright

©

 2010.  Market Central, Inc.  All rights Reserved. 

Market Central

®

 and SwitchMaster

®

 

are registered trademarks of Market Central, Inc. 

Summary of Contents for 6100924-SC

Page 1: ...ount Single FONAC A B Switch with SC connectors Rackmount Market Central Inc 500 Business Center Drive Pittsburgh PA 15205 Phone 412 494 2800 Fax 412 494 5550 www secureswitch com CAGE Code 1BGJ7 Copyright 2010 Market Central Inc All rights Reserved Market Central and SwitchMaster are registered trademarks of Market Central Inc ...

Page 2: ... 62 5 125 µm multimode fiber Crosstalk Less than 45 dB per FOTP 42 Approvals UL cUL TUV PSE and CE power supply Temperature 14 to 149ºF 10 to 65ºC operating 4 to 158ºF 20 to 70ºC storage Relative Humidity 0 to 95 noncondensing Mean Time Between Failures 100 000 hours or 1 000 000 cycles Power 100 240VAC 50 60 Hz wall mount supply 12VDC output Size 6 7 D x 19 W x 1 75 H 1U rackmount Weight 5 lb Rem...

Page 3: ...provides 3 signal pins for remote status indication to allow a programmable controller or similar device to determine the status of connection path through the Fiber Optic Network Access Control A B Switch see table 3 1 3 Installation Place the switch in a location relatively free from vibration and mechanical disturbances Connect your fiber optic cables to the Common port Port A and Port B Note t...

Page 4: ...horted to the Ground contact then the switch will be in the active state Port B connected to the Common Port The switch is in the inactive state Port A connected to the Common Port if power is removed or if both the override switch is in the OFF position and the terminal block Active contact is not connected tothe Ground contact See table below Connection State Power Override Switch Remote Contact...

Page 5: ... the problem including the nature and duration of the problem when the problem occurs the components involved in the problem any particular applications that when used appears to create the problem or make it worse 5 2 Shipping and Packaging If you need to transport or ship your switch Package it carefully We recommend that you use the original container If you are shipping the switch for repair m...

Page 6: ...ective part of parts Correction in the manner provided above shall constitute a complete fulfillment of all obligations and liabilities of Market Central with respect to the quality of said products THE FOREGOING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES OF QUALITY WHETHER WRITTEN ORAL OR IMPLIED INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR PURPOSE TH...

Reviews: