 1

Dear customer,

 

 
Congratulations on purchasing this product. It was manufactured and tested subject to 
strict quality standards and with the utmost care. We thus laid the groundwork for safe 
use. It is now your responsibility to use this product correctly. 
 
For correct and safe use of this product it is essential that you read these instructions 
carefully. Follow all safety instructions in the respective chapters of this manual. 
 
You may only use this product if you have read and understood these instructions for 
use, if you have undergone training and if you are physically and mentally capable of 
doing so.

This manual including the inspection protocol must be kept with the product. In case 
of loss or if manual and inspection protocol became unusable, the effective versions of 
both documents are available for download at www.savealife.at

You can download the instructions for use and the test protocol via www.savealife.at. 

Do you have any questions or wishes concerning this product or do you want to give us 
feedback? Just call us or send an email. 

Customer service

MARK Save A Life GmbH
Gleinkerau 23
4582 Spital am Pyhrn
Austria / Europe
Tel +43 7563 8002 – 111
Fax +43 7563 8041 – 111
[email protected]
www.savealife.at

Manufacturer

MARK Save A Life GmbH, Gleinkerau 23, 4582 Spital am Pyhrn, Austria / Europe

Country of origin

Austria / Europe 
 

Copyright

MARK Save A Life GmbH, Gleinkerau 23, 4582 Spital am Pyhrn, Austria / Europe

NOTE

Summary of Contents for Allstar

Page 1: ...ave A Life GmbH Gleinkerau 23 4582 Spital am Pyhrn sterreich Europa Tel 43 7563 8002 111 Fax 43 7563 8041 111 mark savealife at www savealife at www facebook com makingyourlifesafer Serial number Desc...

Page 2: ...DATA SHEET...

Page 3: ...manual including the inspection protocol must be kept with the product In case of loss or if manual and inspection protocol became unusable the effective versions of both documents are available for d...

Page 4: ...falls from a height long rope end avoid slack rope short rope end In order to make our texts easier to read we dispense with gender differentiation and write main personal words in the male form This...

Page 5: ...11 2 7 Rescue deployment 11 2 8 Overload 11 2 9Temperature 11 3 USE 12 3 1 Intended use 12 3 2 Important notes on the usage of the eyebolts 13 3 3 Abseiling with MARK Allstar 14 3 4 No move during li...

Page 6: ...10 LEGAL INFORMATION 24 10 1 Declaration of conformity 24 10 2 Product liability 24 10 3 Copyright 24 10 4 Trademarks 24 11 DECLARATION OF CONFORMITY 25 12 TEST PROTOCOL 26 13 USAGE OVERVIEW 28 4...

Page 7: ...owing categories are being used DANGER WARNING CAUTION and NOTE Follow the safety instructions to avoid personal injuries or damage of the product DANGER means that death or a serious injury are very...

Page 8: ...safe anymore e g rope damaged etc send it to MARK Save A Life or an authorized partner for inspection and repair Do not use it Fill in the inspection protocol carefully Each inspection must be entered...

Page 9: ...dried in the sun or over a heat source e g radiator Air dry this product in an airy shaded place This product the rope in particular must not be disinfected or impregnated Do not use chemicals when c...

Page 10: ...mantleropel 9 6mm till 11mm EN 1891 A Descent lifting load max 285kg min 30kg EN 3 persons ANSI 2 persons Descent lifting height max 500 m Descent speed approx 1 0 m s with 85kg and approx 1 5 m s wit...

Page 11: ...of people with simultaneous use 4 Max Descent height acc standard multiple use 5 Serialnumber 6 Production year and months 7 Product name 8 Manufacturer 9 Always read and follow the instructions for...

Page 12: ...r Carabiner Anchor device Full body harness Lanyards Workpositioning The above products are featured on www savealife at If you need more information please send us an email or call us 2 5 Maximum des...

Page 13: ...se We recommend using different devices for training and rescue deployments 2 8 Overload Devices that have been subjected to a fall or a heavy load must be retired Rope clamp When you activate the rop...

Page 14: ...efore using this product In case of doubt or if you have questions please contact MARK Save A Life Inspection Using this product without having performed a visual and functional inspection can lead to...

Page 15: ...using the descender as a shuttle system make sure that you use the eye bolts correctly Standard rule Only run the unloaded longer rope end through the eye bolts Longer and shorter rope end If you run...

Page 16: ...he side of the unloaded rope end will add friction when you hold back the unloaded rope end This way you can reduce speed manually 2 Use of the rope clamp In both ways you can block the device after s...

Page 17: ...after stopping by run ning the rope out of the device making a U turn to the eye bolt and back through the rope clamp as shown grab the handwheel while doing this 3 4 No move during lifting If it hap...

Page 18: ...uctions for use for MARK Gekko and MARK Boa checklist for installation and regular inspection checklist inspection protocols installation protocol and sub structure checklist 3 6 Training The customer...

Page 19: ...ter a max of 10 years textile parts must be replaced and metal parts must be inspected by MARK Save A Life The MARK Infini Box has to be inspec ted at least once a year but in any case before each use...

Page 20: ...vice to MARK Save A Life or a authorized person to check and replace the rope Information on work according to EN 341 2011 1A work capacity 7 500 000 Joule work W m x g x h x n W work in Joule J m loa...

Page 21: ...equipment sealed in special packaging NOTE 5 MAINTENANCE 5 1 Repairs Product changes Repairs adjustments or changes to this product that have not been authorized by MARK Save A Life can lead to sever...

Page 22: ...k if nuts and bolts are fixed Check if the rope has cracks or other visual or palpable damage Check if the rope runs smoothly Pull both rope ends slowly one after the other If you feel slight resistan...

Page 23: ...vice Inspection criteria Inspection required by user Inspection required by competent person Inspection required by MARK Save A Life or authorized partner Insepction required only by MARK Save A Life...

Page 24: ...used anymore Retire this product in an environmentally friendly way Separate materials 8 RESALE To ensure safe and correct use this product may only be resold with the instructions for use and the ins...

Page 25: ...body sitting up or squatting Open straps and tight clothes Monitor cardiovascular and respiratory system If the casualty has no signs of life start with CPR If the injured person is suspended but able...

Page 26: ...by the accredited testing inspection and certification body Allgemeine Unfallversicherungsanstalt Adalbert Stifter Stra e 65 1200 Wien with the number Identification number 0511 is subject to the qua...

Page 27: ...11 DECLARATION OF CONFORMITY 25...

Page 28: ...tory number Inspections must be carried out at least once a year by a competent person Date Result remarks Inspector signature Product is OK continue using product Product is damaged retire product Pr...

Page 29: ...tory number Inspections must be carried out at least once a year by a competent person Date Result remarks Inspector signature Product is OK continue using product Product is damaged retire product Pr...

Page 30: ...Usage no Date Usage in meters Signature of user 13 USAGE OVERVIEW DOWNLOAD UNDER WWW SAVEALIFE AT 28...

Page 31: ...Usage no Date Usage in meters Signature of user 13 USAGE OVERVIEW DOWNLOAD UNDER WWW SAVEALIFE AT 29...

Page 32: ...Making your life safer...

Reviews: