marinco INV10120700 User Manual Download Page 1

 
 
 

 

 
 

USER’S MANUAL  

 

INV10120700 / INV20120700 / INV30120700 
INV10121000 / INV20121000 / INV10121500 
INV20121500 / INV30121500 / INV10240700 
INV20240700 / INV10241000 / INV10241500 

INV20121500 

 
 

Pure sine wave inverter  

 

 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

10000006303/05

MARINCO 

N85W12545 Westbrook Crossing 
Menomonee Falls, WI 53051 

www.marinco.com

 

ENGLISH: PAGE 

NEDERLANDS: PAGINA 

13 

DEUTSCH: SEITE 

25 

FRANÇAIS: PAGINA 

37 

CASTELLANO: PÁGINA 

49 

ITALIANO: PÁGINA 

61 

All manuals and user guides at all-guides.com

all-guides.com

Summary of Contents for INV10120700

Page 1: ...INV10241000 INV10241500 INV20121500 Pure sine wave inverter 10000006303 05 MARINCO N85W12545 Westbrook Crossing Menomonee Falls WI 53051 www marinco com ENGLISH PAGE 1 NEDERLANDS PAGINA 13 DEUTSCH SEI...

Page 2: ...attery to the DC input Integrate a fuse holder in the positive battery wire but do not place the fuse yet Black wire NEG Red wire POS Connect red wire to black wire to Incorrect polarity will damage t...

Page 3: ...ing point of the vehicle ship The neutral conductor N of the AC output of the Inverter must be connected to the safety ground PE GND and a ground fault circuit interrupter GFCI must be integrated in t...

Page 4: ...ltage of the Inverter e g 24V battery for a 24V input voltage Also check that the output voltage satisfies loading requirements A DC fuse holder must be integrated in the positive wiring The DC fuse s...

Page 5: ...of LED indicators 3 4 and 5 INPUT LEVEL ref 3 displays the input voltage of the inverter Input voltage V Indication of the LED 12V models 24V models RED blinking slow 10 3 10 6 20 5 21 2 RED 10 6 11 0...

Page 6: ...e the load and let the inverter cool down The inverter will switch on again when the internal temperature is 45 C 113 F Airflow insufficient Check the airflow through the inverter The operation of the...

Page 7: ...3V 0 5V 14 3V 0 5V 28 6V 0 5V Maximum allowed ripple on DC 5 RMS Input current nominal load 64A 32A 64A 64A 32A External DC fuse required 100A 50A 100A 100A 50A Recommended battery capacity 100Ah 55Ah...

Page 8: ...A 92A 46A External DC fuse required 150A 150A 80A Recommended battery capacity 120Ah 120Ah 100Ah DC cable up to 3m 10ft 35mm 2AWG 35mm 2AWG 25mm 4AWG No load power consumption Off mode 0mA 0mA 0mA Pow...

Page 9: ...28 6V 0 5V 14 3V 0 5V 28 6V 0 5V Maximum allowed ripple on DC 5 RMS Input current nominal load 125A 125A 64A 125A 64A External DC fuse required 200A 200A 100A 200A 100A Recommended battery capacity 1...

Page 10: ...000 Watt 88 3 5 1500 Watt 88 3 5 700 Watt 179 7 0 1000 Watt 182 7 2 1500 Watt 191 7 5 700 Watt 151 5 9 1000 Watt 154 6 0 1500 Watt 163 6 4 S3 S2 PWR SAV I O S1 LOAD LEVEL INPUT LEVEL S4 STATUS FREQ SI...

Page 11: ...le errors in this manual and the consequences of these Damage due to use that is inconsistent with the purpose of the product EC DECLARATION OF CONFORMITY We Manufacturer Marinco Address N85 W12545 We...

Page 12: ...12 MARINCO N85W12545 Westbrook Crossing Menomonee Falls WI 53051 Phone 800 307 6702 or 262 293 1700 Fax 262 293 7022 Email info Marinco com All manuals and user guides at all guides com...