DSM570
User’s Manual
Page 252
Revision 1.8.3
This brings up the list of Alerts managed by the DSM570.
Figure 298
– Editing an Alert: Alert List
The following information is shown for each alert that is in the system.
Priority
– The priority of the Alert (see 8.3.3).
Enab
.
– Whether the Alert is Enabled or Disabled.
Type
– The Type of Alert. This is a combination of whether the Alert is Local or Global (8.3.15)
and whether the Alert is an Alarm or a Warning (4.3.1)
Description
– The textual description of the Alert (8.3.5)
Scroll up and down using the
Scroll Up
and
Scroll Down
buttons until the alert that must be edited is
highlighted and press the
Enter
button.
The Alert Editor is opened, pre-populated with the parameters of the chosen Alert. See Section 8.1
for details of these parameters.
8.6 Setting the Vessel Operating Mode
The Vessel Operating Mode must be set on each DSM570. This is a potentially risky operation, in
that Alerts that are Active in the existing mode may be ignored in the new Operating Mode. The
DSM570 will warn the operator about these Alerts to minimize the risk. However, if the new vessel
status was transmitted to other Alert Sources that are unmanned, then the warnings would be lost.
For this reason, the Vessel Operating mode must be changed at each DSM570 or N2Kview, and
those alerts, which would be disabled, noted by the user.
The Vessel Operating Mode is set through the Alert Setup Screen.
Scroll Down
to the required
Operating Mode entry, press
Enter
and then use the
Scroll Up
/
Scroll Down
buttons to select the
new Mode. Press
Enter
to complete the operation.