Marco Beverage Systems QWIKBREW 2 TWIN 5.6kW Instructions Manual Download Page 1

 

 

 

 

Marco Beverage Systems Ltd. 

 

 

 
 
 

INSTRUCTIONS FOR MODELS 

 
 
 
 

QWIKBREW 2 TWIN 5.6kW 

(P/N: 1000495) 

 

QWIKBREW 2 TWIN 8.4kW 

 (P/N: 1000485) 

 

 
 
 
 
 
 

Water  pressure

 

:

 5 - 50 psi (min.-max.)35 - 345 kPa (min.-max.)

 

 

 

 
 

 
 
 

Marco Beverage Systems Limited. 

63d  Heather Road, 
Sandyford Industrial Estate, 
Dublin 18. 

Marco Beverage Systems Limited. 

Shire House, Strixton Manor,  
Strixton, Wellingborough, Northants, 
NN29 7PA 

Ireland Tel: +353 (0)1 295 2674 
Ireland Fax: +353 (0)1 295 3715 
email: [email protected] 
www.marco.ie 

UK Tel: +44 (0)2072 744 577 
UK Fax: +44 (0)2079 788 141 
email: [email protected] 
www.marco-bev.co.uk

 

Summary of Contents for QWIKBREW 2 TWIN 5.6kW

Page 1: ...co Beverage Systems Limited 63d Heather Road Sandyford Industrial Estate Dublin 18 Marco Beverage Systems Limited Shire House Strixton Manor Strixton Wellingborough Northants NN29 7PA Ireland Tel 353...

Page 2: ...raight tailpiece of the inlet hose to the stop valve fitting Make sure that the pre attached sealing washer is fitted Turn on the water to flush any impurities dust etc from the inlet hose and water p...

Page 3: ...tinuous fill mode essentially keeps the machine full of water regardless of temperature In this mode the machine will never run out of water but misuse e g filling buckets for cleaning can allow cold...

Page 4: ...itres Depending on the coffee grind and roast and on water quality you may have to adjust these quantities to obtain the optimum flavour Level off the surface of coffee by gently shaking the filter bo...

Page 5: ...the machine can recover will result in a temperature drop in the beverage Continuous fill mode Note A brew can still be selected after all the hot water has been drawn off the hot water tap While the...

Page 6: ...the following page Note Two flash and six flash error sequences will be displayed if there is low water pressure Please check that there is water pressure and that the water stop valve is open before...

Page 7: ...nts every 6 months should suffice CLEANING Like any cooking utensils the coffee urns of your Qwikbrew 2 Twin must be cleaned properly and regularly Marco recommend cleaning after each days brewing usi...

Page 8: ...ating the water drawoff tap especially when cleaning the front of the boiler ALL users of this machine should be trained and should be aware that the machine dispenses very hot beverages The utmost ca...

Reviews: