Unit Setup
3
Lift up the handle of the module and use it to pull the module out of the recorder.
4
Insert the new power supply module into the recorder until it clicks into place.
5
Plug the AC power cord into the new power supply module.
The LED on the new module turns green to indicate that it is functioning correctly.
Replacing a Redundant Power Supply Module in a 1U Recorder
The power supply modules for the 1U recorder have a lever at the top right of each module to
unlock the module from the recorder unit. The functioning power supply module remains plugged
in so that the recorder never loses power during the replacement process.
To replace a redundant power supply module in a 1U model
1
The LEDs on the back of the power supply modules indicate which module has failed and
requires replacing. Only unplug the power cord from the failed module. DO NOT unplug the
functioning module.
2
On the module that you want to replace, move the lever at the top right of the module down to
unlock the module from the recorder unit.
3
Pull the handle of the module so that the module slides out of the recorder.
4
Insert the new power supply module into the recorder until it clicks into place.
5
Plug the AC power cord into the new power supply module.
The LED on the new module turns green to indicate that it is functioning correctly.
Unlit LED indicates
Green LED indicates module
is functioning correctly
module not functioning
Note:
Photo does not show
power cords. Do not
unplug functioning
module.
Move lever down
Handle of module