2-2.4. Clearing the Protection History
There are two ways to clear the protection history.
(a) Activate Protection History Display Mode. Press the "
STATUS
" button to display the protection history. Press and
hold the "
DIMMER
" button for 3 seconds.
FLD
L1
P R O T E C T
L2
H I S T O R Y
L3
: D C
Press and hold the "
DIMMER
" button for 3 seconds.
FLD
L3
C L E A R
The above message is displayed and the protection history is cleared.
FLD
L2
: N O
(b) Initialize this unit. (See "
Initializing This Unit"
b
Use the method in
2-2.4. Clearing the Protection History (a) if you do not want to erase your settings from this unit.
Warning Displays by POWER LED
If the power is turned off while a protection is being detected, the POWER LED flashes in red to warn you depending on
the protection status as follows.
(a) ASO/DC protection: Flashes at 0.5-second intervals (0.25 seconds lit, 0.25 seconds unlit)
(b) THERMAL (A/E/F) protection: Flashes at 2-second intervals (1 seconds lit, 1 seconds unlit)
(c) CURRENT protection: Flashes at 4-second intervals (2 seconds lit, 2 seconds unlit)
2-3. 232C Standby Clear Mode
2-3.1. Actions
Switches from 232C standby mode to normal standby mode.
2-3.2. Starting up
While holding down buttons "
STATUS
" and "
ZONE2 SOURCE
" simultaneously, press the power button to turn on the
power.
Select the "
3.RS232C RESET
" using the "
TUNER PRESET CH+/-
" button, then press the "
STATUS
" button then to con-
firm.
Switches from 232C standby mode to normal standby mode.
67