Make sure to initialize this unit after replacing the microcomputer or any peripheral equipment, or the
PCB.
1. Insert the AC plug while pressing buttons "
SOURCE DIRECT" and "BACK" together, and wait for more
than 3 seconds.
2. "
Factory Reset
" is shown on the display for 5 seconds.
"
Factory Reset
" is displayed for 5 seconds, then the language selection screen is displayed.
Network function settings are not initialized.
NOTE: • If the unit fails to enter the service mode in step 2, repeat the procedure from step 1.
• Initializing the device restores the customized settings to the factory settings. Write down
your settings in advance and reconfigure the settings after initialization.
BACK
SOURCE DIRECT
Initializing this Unit
POST-SERVICE PRECAUTIONS
Use network initialization mode to initialize the network related settings.
1. While the power is On, hold down buttons "
POWER" and "BACK" for at least 3 seconds.
2. "
Please wait
" is displayed. (Language : case of English)
Changes between ".", then ".." and "..." for 1 second each.
3. "
Completed
" is shown on the display for 5 seconds. (Language : case of English)
4. After this is displayed for 5 seconds, the display returns to the SOURCE display that was shown before
the Network Function Reset.
・All settings, including network function settings, are initialized.
Before Servicing
This Unit
Electrical
Mechanical
Repair Information
Updating
7