17
1.tHe PoWeR CAN Not Be tURNeD oN
(StANDBY LeD DoeS Not LIGHt (StANDBY MoDe))
Check linsertion of the 8U-110131-4
STANDBY PWB UNIT.
Check linsertion of the 8U-210120-1
STANDBY PWB UNIT.
Broken wire in SUB
TRANS T8501.
Malfunction of
D8501-8507.
Malfunction of
D8501, U1001.
Check whether power is being
supplied to the coil of the SUB
TRANS T8501.
Check whether power
is being supplied to
the D8501-8507.
Power not supplied.
Power not supplied.
Power supplied.
Power supplied.