5.3. Error display
E1-00 : Disc cannot be detected.
E1-01 : Tracking offset adjustment not possible.
E1-02 : Focus offset adjustment not possible.
E2-00 : The focus servo was disabled during playback.
E2-01 : The focus servo was disabled during searching.
E2-03 : The focus servo was disabled during TOC reading.
E2-06 : The focus servo was disabled during manual search.
E2-10 : Subcode became unreadable during playback.
E2-11 : Subcode became unreadable during searching.
E2-12 : Subcode became unreadable during TOC reading.
E2-14 : Subcode cannot be read while pausing.
E2-15 : Subcode cannot be read during manual search.
E3-00 : TOC could not be read within the specified time.
E3-01 : PVD/SVD analysis was not be completed within the specified time.
E4-04 : Search time out
E4-05 : Error in communications with CD decoder
E5-00 : Inner switch is not on.
E6-00 : Inner switch is not off.
E9-00 : CD u-com error
E9-01 : Other error
z
X-XX : Error cord
Heat run count at the time the error occurred
• Press the "
7
/
9
" button while the error is displayed.
• The heat run count is displayed for 5 seconds before returning to the error code display.
z
XXXX: heat run repetition count
The track number and elapsed playback time where the error occurred is displayed.
• Press the "
8
/
6
" button while the error code is displayed.
• The track number and elapsed time of the track at the time the error occurred are displayed for 5
seconds before returning to the error code display.
z
" _ C D _ _ _ x x Tr _ _ m m : s s "
z
xx : Track Number of error occurred.
z
mm:ss: elapsed time of track at the time the error occurred
X
X
X
X X X
X
6. Accumulated laser on time display mode
While holding down buttons the "
8
/
6
" and "
3
" buttons simultaneously, insert the AC plug to turn
the power on.
• One count corresponds to 10 minutes. (Values under 10 minutes are discarded)
• The retained data is not updated after 10922 hours. (The display will continue to read 10922.)
Resetting the count value
• With the accumulated laser-on time displayed, press and hold the "
1
" button for over 5 second to
reset the count value (overwrite the stored data).
• The display returns to the display in 6. ("00000 hour" at top) after initialization is completed.
• The Count value is reset upon shipment from the factory and when the mechanism is replaced.
7. Timer check mode
Not for service.
This mode is cancelled when the power is turned off.
8. Over Current display
If an electric current of over 1A flows in USB-A, then this message will display.