You have now done your part in creating this sample project. It is now time for EZware-500 to do its part.
Fin ishing Up
There are still a few steps, which must be completed before you can test your first project. In this section, you will:
·
save the project onto your computer hard drive
·
compile the project into a format that can be understood by the OIT
·
download the project to the OIT
·
verify that the OIT operates as expected
·
exit the EZware-500 software
If you haven’t already done so, now would be a good time to connect the OIT to the
computer and to connect the PLC that you are using to the OIT. For more information,
consult the first part of this chapter or see “Installation of OITs” later on in this
manual.
4
Saving your first project
1.
From the File menu, click
Save As
. The Save As dialog box appears.
2.
In the File name text box, type
EBPrj1
.
3.
Click
Save
. The file is saved onto your computer hard drive and the main screen of
EasyBuilder reappears.
4
Compiling your first project
1.
From the Tools menu, click
Compile
. The Compiling dialog box appears.
2.
Click
Compile
. EasyBuilder will compile your project and display error results.
3.
If no errors occur, click
Close
. The main screen of EasyBuilder reappears. If errors have
occurred, repeat the steps in the
Creating a Sample Project
section.
4
Downloading your first project
1.
Apply power to your OIT.
2.
From the Tools menu, click
Download
. The EasyDownload Complete Project dialog box
appears.
3.
If the OIT is correctly connected to the computer, then the download process will begin. You
will notice that a horizontal bar graph is displayed on the computer indicating how much of
the project has been downloaded. The OIT will also display several Write Flash commands
that scroll on the screen. If a timeout error is displayed, please review your connection of the
OIT to the computer and make sure that the appropriate settings in EasyManager are used.
4.
After the download is finished, the Mission Complete dialog box is displayed.
5.
Click
OK
. The main screen of EasyBuilder reappears.
6.
You will now use EasyManager to get the OIT to execute the project you just downloaded. If
you want to exit EasyBuilder, from the File menu click
Exit
.
4
Displaying your project on the OIT
1.
From the Windows Task Bar, click
EasyManager
. The EasyManager dialog box appears.
2.
Click
Jump To Application
. This will send a command to the OIT to run the project.
1010-1001a, Rev 02
26
Sil ver Se ries In stal la tion & Op er a tion Man ual
Summary of Contents for Silver HMI504T
Page 1: ...1010 1001A Rev 02...
Page 32: ...1010 1001a Rev 02 28 Silver Series Installation Operation Manual...
Page 128: ...1010 1001a Rev 01 124 Silver Series Installation Operation Manual...
Page 156: ...1010 1001a Rev 02 152 Silver Series Installation Operation Manual...
Page 166: ...1010 1001a Rev 02 162 Silver Series Installation Operation Manual...
Page 216: ...1010 1001a Rev 01 212 Silver Series Installation Operation Manual...
Page 251: ...1010 1001a Rev 02 Macros 247 Set Bit Objects Attributes Dialog Project Example of Add 2...
Page 264: ...End Macro_Command 1010 1001a Rev 02 260 Silver Series Installation Operation Manual...
Page 268: ...1010 1001a Rev 01 264 Silver Series Installation Operation Manual...