9
D00729EN - v2
DDS-SSENSOR
- INSTALLATION MANUAL
2.3 SAFETY FIELD SETTING - INFRARED
Press twice to activate the
visible spot.
1
If necessary, adjust the angle of the
infrared curtains (from -7º to +4º)
2
Part of the emitted field can be covered in order to reduce the detection field.
The position of the arrow determines the field width.
Always check the field width with a
piece of paper and not with the
Spotfinder, that detects the entire
emitted field.
Possible
additional
settings
through
the LCD.
≤ 9 cm
*Visibility depends on external conditions. If the spots are not visible, the Spotfinder helps to locate the position of the curtains.
**The distance between the inner curtain of the inside door sensor and the inner curtain of the outside door sensor should always be
less than 20cm
The distance up to the door leaf depends therefore on the thickness of the door leaf.
CLOSER
FARTHER
2.4 OTHER SETTINGS
Set the sensor by LCD or choose one of the presettings:
1.- STANDARD
: indoor mounting
2.– CRITICAL ENVIRONMENT
: critical or outside installations
3.– SHOPPING STREET
: Installations in narrow streets with pedestrian traffic
Presettings
Standard
Presettings
Critical env.
Presettings
Shopping str.
A
N
G
LE
WI
DTH
x2
The size of the detection fields varies depending on the mounting height and the settings of the sensor. The sensor should
cover the whole travel path of the door leaf/leaves. To verify, use the reference body as per EN 16005 (reference body
dimensions: 700x300x200mm).
Cuerpo de referencia