Manson Engineering Industrial SSP-9081 User Manual Download Page 1

SSP-9081 

 

REMOTE PROGRAMMABLE POWER SUPPLY 

WITH 

ETHERNET NETWORK CONNECTIVITY 

DC WAVE FORM GENERATOR 

3 SELECTABLE VOLTAGE & CURRENT RANGES 

 

USER MANUAL 

 

 
 
 
 
 
 
 
 

Summary of Contents for SSP-9081

Page 1: ...SSP 9081 REMOTE PROGRAMMABLE POWER SUPPLY WITH ETHERNET NETWORK CONNECTIVITY DC WAVE FORM GENERATOR 3 SELECTABLE VOLTAGE CURRENT RANGES USER MANUAL ...

Page 2: ...DURES 7 5 1 Adjusting Output Voltage and Current 7 5 2 Upper Voltage and Current Limit adjustment 8 5 3 Select and adjust 3 preset value of Voltage and Current 9 5 4 Output ON OFF Include power up ON OFF setting 9 5 5 Lock Unlock of front panel 9 5 6 Watt meter and Amp meter selection 9 5 7 Ramp Up Ramp Down generator 10 5 8 Master Slave configuration 14 5 9 Factory reset 15 5 10 Remote control in...

Page 3: ...cause damage to the power supply 7 The gauge size of input power cable must be at least 0 75mmsq and the total length of power cable must not exceed 3m 8 Input Fuse Recommended T2AL250V Time Lag from 2A 1 3 Operation environmental condition 10 80 R H Altitude up to 2000m Installation category CAT 2 Pollution degree 2 Mains supply voltage fluctuation up to 10 of the specified operating voltage 2 IN...

Page 4: ...Step Irregular Waveform functions Number of Voltage Level Setting 10 Settable Output Time Period of each Voltage Level 0 to 600 seconds Remote Programmable Control by PC Output ON OFF Voltage Current Control Selection of Voltage and Current Preset Programmable of cyclic output and data logging of output Upper Voltage Current Limit control Protection Tracking Over Voltage Protection Current Limitin...

Page 5: ...ate the lower part 4 digits LED is watt meter The value is showing output power Remote Control Indicate the Power Supply is under remote control Whenever you connection power supply using control software through USB or Ethernet This LED will be ON SLAVE Indicate the Power Supply is in slave mode and control by master unit The voltage and current setting of slave units are being set to value of ma...

Page 6: ...voltage and current will set preset A value Preset B Indicate Preset B is selected the output voltage and current will set preset B value Preset C Indicate Preset C is selected the output voltage and current will set preset C value 4 2 Control Buttons and Knobs The power supply has 2 knobs and 6 buttons Voltage adjust knob Current adjust knob Output ON OFF button Preset program A selection button ...

Page 7: ...SE output voltage Rotate Voltage Knob anti clockwise to REDUCE output voltage Press Voltage knob to switch between COARSE and FINE adjustment When press the knob the digit will been high lighted for adjust Adjust Output Current Rotate Current Knob clockwise to increase output voltage Rotate Current Knob anti clockwise to reduce output voltage Press Current knob to switch between COARSE and FINE ad...

Page 8: ...ll show as follow Rotate Voltage Knob to adjust the value Press to confirm setting If the new UVL value is lower than set voltage it will show UVL Error alert Just reduce the set voltage to lower than the UVL value Then the UVL Error will OFF Upper Current Limit UCL The Upper Current Limit is feature to let user to set maximum value for current adjustment This feature can help to prevent accidenta...

Page 9: ... output ON OFF setting The power up output ON OFF status can be configured according to usage requirement The default setting is output OFF when system power up It has option to set as SAME AS LAST STATUS That means the output ON OFF status will same as status before power off Steps to change setting Step 1 Press and hold to enter menu Step 2 Rotate Volt Knob to select PU menu The display shows St...

Page 10: ...urr Knob to change value of set items The below table shows the available set items and value range for dvdt menu Set Item Description Value Range Number of steps to be use for wave form generation Must start from step 1 2 10 Number of cycle to run for wave form 0 to 999 0 means run forever Step 1 to Step 10 Voltage setting in V 0 to 36V Step 1 to Step 10 run time length in S 0 to 600s Step 6 Pres...

Page 11: ...Step 2 voltage to 12V 3 Set Step 2 run time to 3s Ramp DOWN from step 2 voltage to step 1 voltage in 3s Example 2 Saw tooth waveform Setting value Set Item Value Explaination 2 Set 2 steps to run Step 1 and Step 2 6 Run 6 cycle only 2 5 Set Step 1 voltage to 2 5V 3 Set Step 1 run time to 3s Ramp UP from step 1 voltage to step 2 voltage in 3s 12 Set Step 2 voltage to 12V 0 Set Step 2 run time to 0s...

Page 12: ... Edge UP from step 1 voltage to step 2 voltage in 0s 12 Set Step 2 voltage to 12V 3 Set Step 2 run time to 3s Keep at 12V by 3s since step 2 voltage step 3 voltage 12 Set Step 3 voltage to 12V 0 Set Step 3 run time to 0s Edge DOWN from step 3 voltage to step 4 voltage in 0s 2 5 Set Step 4 voltage to 2 5V 5 Set Step 4 run time to 5s Keep at 2 5V by 5s since step 4 voltage step 1 voltage P 12 ...

Page 13: ...et Step 3 voltage to 12V 4 Set Step 3 run time to 4s Ramp UP from step 3 voltage to step 4 voltage in 4s 17 Set Step 4 voltage to 17V 0 Set Step 4 run time to 0s Edge DOWN from step 4 voltage to step 5 voltage in 0s 7 8 Set Step 5 voltage to 7 8V 3 Set Step 5 run time to 3s Keep at 7 8V by 3s step 5 voltage step 6 voltage 7 8 Set Step 6 voltage to 7 8V 5 Set Step 6 run time to 5s Ramp DOWN from st...

Page 14: ...e to 5 units will make every unit carry 2Amp Every units in same Master Slave connection should assign an unique address ID The Master unit should be address ID 0 factory default The Slave address can be from 1 to 30 Steps for Changing the address ID Step 1 Press and hold button to enter setting menu Step 2 Rotate VOLT knob to select address menu The display shows Step 3 Press VOLT knob to enter a...

Page 15: ...ter setting menu Step 2 Rotate VOLT knob to select UNS menu The display shows Step 3 Press VOLT knob to enter UNS menu The display shows Step 4 Rotate CURR knob to change from to for Ethernet interface Step 5 Press VOLT knob to confirm Step 6 Press to exit menu 5 11 Boot loader mode Firmware upgrade The SSP 9081 provide firmware upgrade feature for upgrade to latest firmware It require firmware up...