Manson Engineering Industrial DPM-3321 User Manual Download Page 1

DPM-3321 

 

Bi-directional Digital DC Power Meter 

with built-in USB data logger & adapter 

External shunt model 

 

User Manual 

 

Bi-Directional DC Power Meter with built-in USB data logger & adapter. 

 

The new DPM-3321 is an upgrade version of previous DPM series. It measures current in both 

direction, using a battery as the reference, it measures the Charging and Discharging current. 

DPM-3321 is a self contained with built in data adapter for data retrieval to PC* via USB port and 

for real time monitoring. 

In addition to USB, it can be connected through Bluetooth* for Bluetooth model. The new EEPROM 

is increased to 3,600 sets of data. 

The direction of current is with reference to the receiving end (output) typically a battery. 

Current(charging) going to battery is Positive (+) and current out of battery (discharging) is 

Negative(-). 

The power meter is powered up by 5-60V dc from either side or an external USB power bank for 

extended measured dc voltage range of 0-60V. 

 

*Remark:  PC software, driver, software and Bluetooth manual can be download from 

 

http://www.manson.com.hk/product/dpm-3321/ 

 

Precaution 

 

a.  Do not exceed 60V DC in application of DC Meter. 

b.  This meter is designed and made for indoor use only. 

c.  Do not disassemble or attempt to repair the power meter. 

d.  If Start up screen does not appear, immediate remove all input and output connections power 

 

sources. 

e.  Double check on the correct polarity. If either input or output connection is in wrong polarity, 

 

there is no display on LCD. 

f.  Damage to the Power Meter may result if wrong polarity power is applied. 

g.  Do not exert pressure on the display to avoid damage to LCD display. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for DPM-3321

Page 1: ...battery Current charging going to battery is Positive and current out of battery discharging is Negative The power meter is powered up by 5 60V dc from either side or an external USB power bank for ex...

Page 2: ...t Hour Vp max voltage Ap max current Wp max Watt Vm min Voltage Negative Ah WH AP Wp back to Time period in use Freeze Scrolling display Hold and release of any scrolling display by quick press of RES...

Page 3: ...Wiring Diagram Bi directional Connections with 5 60V DC range...

Page 4: ...al application with external DC for 0 60V meter range Bi directional application connect to PC Remark PC software driver software and Bluetooth manual can be download from http www manson com hk produ...

Page 5: ...tional Connections When used in unidirectional applications there is no negative current The following are some examples for meter connections Unidirectional application with external DC for 0 60V met...

Page 6: ...Unidirectional Application Connect to a PC Remark PC software driver software and Bluetooth manual can be download from http www manson com hk product dpm 3321...

Page 7: ...PM In case it is need to change the DPM shunt rating to match your shunt proceed as following 1 Disconnect phone plug from shunt 2 Press and hold the reset button Then reconnect the phone plug to shun...

Page 8: ...on to change value in the digit 4 PRESS and HOLD the RESET button to confirm the chosen digit in the number It will show OK then go to set next digit 5 Repeat step 3 and step 4 for all digits 6 After...

Page 9: ...age over the last screen update interval Vp is the Peak maximum voltage Vm minimum from the source side since start up screen to the present moment There is no negative Vp or Vm registered Charge Amp...

Page 10: ...can be reset to 0 by using reset button Press and hold the Reset button until the LCD display show Press again 5 seconds to reset Then release the Reset button quickly press again and hold 5 seconds...

Page 11: ...Discharger Data Log Graph...

Page 12: ...10 000W Energy Kilo Watt Hour KWH Max recorded KWH 9999 9KWH 999 9KWH Resolution of KWH 0 1KWH Registered Peak Voltage Vp Min Voltage Vm Peak Current Ap Negative Peak Current Ap The new high and low v...

Reviews: