QUIET 150mm Extraction Fan

SPECIFICATIONS

Duct

(mm)

Max. 

Fan Watts

(W)

Max. 

Fan 

Pressure

(Pa)

Free Air Fan Performance

Specific

Fan

Power
(W/l/s)

Sound

dB(A)

Operating

Temperature

(max.)

IP 

Rating

(l/s)

(m

3

/hr)

150

22

138

114

410

0.19

41

40°C

IPX4

Compliance: AS/NZS60335-2.80:2016

These axial fans are designed for easy installation, low running noise and effi cient 
operation. 

For best results, Simx recommend this product for bathrooms and kitchens.

In kitchen installations, do not install the fan, laterally, any closer than 2m from the 
cooktop.  

In bathroom installations the fan can be installed within 1.5m, laterally, of the 
steam source and immediately above the bath or shower tray up to the higher of 
either 2.25m or the height of the fi xed plumbing connection. 

Once installed, following these instructions, this product will meet the Healthy 
Homes Standard for bathroom or kitchen installations in a rental property.

This product will also comply with the G4 Building Code for bathrooms and 
kitchens.

A

227

B

30.5

C

111

D

146

DIMENSIONS

A

A

C

D

B

CAUTION

•  Before use, please check that the supply voltage and that of the appliance are the same (see product rating label).

•  All wiring and wiring connections must comply with all current national wiring rules and regulations including AS/NZS3000:2018, or latest   
 edition 

thereof.

•  Any changes or modifi cations made or attempted to this product, without the prior written approval of the manufacturer, will void any and all  
 stated 

warranties.

•  This fan is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and  
 

knowledge, unless they are capable of, and have been given supervision or instruction concerning use of the appliance by a person responsible  

 

for their safety.

•  Precautions must be taken to avoid the back fl ow of combustion gases from the open fl ue of gas or other fuel-burning appliances in the room,  
 

or from other rooms. These gases can potentially result in carbon monoxide poisoning. Open fl ued gas appliances should be tested by a    

 

competent person, after fan installation, to ensure that back fl ow of combustion gases does not occur.

WARNING

•  Do not insert or allow foreign objects to enter any ventilation openings, as this may cause an electric shock, fi re or damage to the fan.

•  Do not put fi ngers or foreign objects into the grille while in operation.

•  To prevent overheating of this fan, keep the air inlets and outlets clean and free of anything that may cause blockage. Check all inlets and   
 

outlets from time to time to ensure it is clear of any dirt or dust accumulation. DO NOT COVER.

•  Do not use it in areas where gasoline, paint, or fl ammable liquids are used or stored.

•  This product contains recyclable materials. Do not dispose of this product as unsorted council waste. Please contact your local council for the  
 

nearest collection point. 

WHEN USING ELECTRICAL APPLIANCES, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE 

FOLLOWED TO REDUCE THE RISK OF PROPERTY DAMAGE OR PERSONAL INJURY.

ALL ELECTRICAL WORK MUST BE CARRIED OUT BY A REGISTERED ELECTRICIAN IN 

ACCORDANCE WITH THE LATEST WIRING RULES AS/NZS3000.

Mounting

Switching

Product Code

Wall or Ceiling

Standard

FAN7183

Timer

FAN7184

Humidity Control

FAN7185