SPECIFICATIONS

Duct

(mm)

Max. 

Fan Watts

(W)

Max. 

Fan 

Pressure

(Pa)

Free Air Fan Performance

Specific

Fan

Power
(W/l/s)

Sound

dB(A)

Operating

Temperature

(max.)

IP 

Rating

(l/s)

(m

3

/hr)

125

15

68

54

194

0.28

38

40°C

IPX4

Compliance: AS/NZS60335-2.80:2016

Mounting

Switching

Product Code

Wall or Ceiling

Standard

FAN7180

Timer

FAN7181

Humidity Control

FAN7182

These axial fans are designed for easy installation, low running noise 
and effi cient operation. 

For best results, Simx recommend this product for bathrooms. 

In bathroom installations, do not install the fan, laterally, any closer 
than 1.5m from the steam source.  

Once installed, following these instructions, this product will meet the 
Healthy Homes Standard for bathroom and kitchen installations in a 
rental property.

This product will also comply with the G4 Building Code for 
bathrooms.

A

187

B

29

C

100

D

120

DIMENSIONS

A

A

C

D

B

CAUTION

•  Before use, please check that the supply voltage and that of the appliance are the same (see product rating label).

•  All wiring and wiring connections must comply with all current national wiring rules and regulations including AS/NZS3000:2018, or latest   
 edition 

thereof.

•  Any changes or modifi cations made or attempted to this product, without the prior written approval of the manufacturer, will void any and all  
 stated 

warranties.

•  This fan is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and  
 

knowledge, unless they are capable of, and have been given supervision or instruction concerning use of the appliance by a person responsible  

 

for their safety.

•  Precautions must be taken to avoid the back fl ow of combustion gases from the open fl ue of gas or other fuel-burning appliances in the room,  
 

or from other rooms. These gases can potentially result in carbon monoxide poisoning. Open fl ued gas appliances should be tested by a    

 

competent person, after fan installation, to ensure that back fl ow of combustion gases does not occur.

WARNING

•  Do not insert or allow foreign objects to enter any ventilation openings, as this may cause an electric shock, fi re or damage to the fan.

•  Do not put fi ngers or foreign objects into the grille while in operation.

•  To prevent overheating of this fan, keep the air inlets and outlets clean and free of anything that may cause blockage. Check all inlets and   
 

outlets from time to time to ensure it is clear of any dirt or dust accumulation. DO NOT COVER.

•  Do not use it in areas where gasoline, paint, or fl ammable liquids are used or stored.

•  This product contains recyclable materials. Do not dispose of this product as unsorted council waste. Please contact your local council for the  
 

nearest collection point. 

WHEN USING ELECTRICAL APPLIANCES, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE 

FOLLOWED TO REDUCE THE RISK OF PROPERTY DAMAGE OR PERSONAL INJURY.

ALL ELECTRICAL WORK MUST BE CARRIED OUT BY A REGISTERED ELECTRICIAN IN 

ACCORDANCE WITH THE LATEST WIRING RULES AS/NZS3000.