4-16
Description of Diagnostic Letters B..., C..., D... and A...
ECODRIVE03 SMT-02VRS
DOK-ECODR3-SMT-02VRS**-WA01-EN-P
Cause:
1.
External encoder cable defective.
2.
Defective feedback.
3.
Defective measurement system interface.
Note:
If this warning occurs in combination with an EnDat feedback
device then the feedback device is defective.
Remedy:
For 1.
Check the optional feedback cable.
For 2.
Exchange feedback.
For 3.
Exchange the measuring system interface (module).
See also the functional description "S-0-0128, C200 Communication
phase 4 transition check".
C223 Input value for max. range too high
Cause:
An internal position resolution has been selected via the S-0-0278,
Maximum travel range parameter that no longer guarantees a correct
commutation of the motor.
Remedy:
Select a smaller value for the S-0-0278, Maximum travel range
parameter.
See also the functional description "S-0-0128, C200 Communication
phase 4 transition check".
C227 Modulo range error
Cause:
The marginal conditions for modulo processing were not maintained.
See functional description: "Modulo Processing-Limiting Conditions".
C234 Encoder combination not possible
Cause:
The encoder interface that has been selected in the P-0-0075, Interface
Feedback 2, optional parameter cannot be supported by the drive; it has
already been allocated to the motor encoder.
Remedy:
Select another optional encoder.
See also the functional description: "Determining the Encoder Interface of
the Optional Encoder"
Summary of Contents for ecodrive03
Page 4: ...About this Documentation ECODRIVE03 SMT 02VRS DOK ECODR3 SMT 02VRS WA01 EN P Notes ...
Page 12: ...VIII Contents ECODRIVE03 SMT 02VRS DOK ECODR3 SMT 02VRS WA01 EN P Notes ...
Page 16: ...1 4 Diagnostic Message Descriptions ECODRIVE03 SMT 02VRS DOK ECODR3 SMT 02VRS WA01 EN P Notes ...
Page 122: ...Index ECODRIVE03 SMT 02VRS DOK ECODR3 SMT 02VRS WA01 EN P Notes ...
Page 127: ......