4-30
ECODRIVE DKC drive controllers
ECODRIVE DKC01.1/DKC11.1 Drive Controllers
DOK-ECODRV-DKC01/11.1*-PRJ3-EN-P
X5, X6, X7 motor connections
For the terminal connection assignments to the motor connections, refer
to the overall connection diagram in Fig. 4-15.
For further information, please see the documentation "ECODRIVE ser-
vomotors MKD" - Project Planning Manual -.
X9 DC bus connection
Note: Does not apply to DKC01.1-030-3-FW!
DC bus connection for connecting:
an auxiliary bleeder module BZM01.1
- or -
an auxiliary capacitance module CZM01.1
- or -
a DKC drive controller
The maximum line length is 1.0 m (twisted) with at least a 2.5 m² cross
section.
AP0206.FH5
Intermediate circuit connection
on DKC01.1-040-7-FW
on DKC11.1-040-7-FW
L+1
L+2
L-1
L-2
1
2
3
4
Intermediate circuit voltage between L+ and L-: DC (500...800) V
X9
Fig. 4-42: DC bus connection