10
Part Number 000007646 Rev 02 5/20
Electrical
n
Warning
All wiring must conform to local, state and national codes.
SPECIFICATIONS
Electric Voltage –
Cycle – Amp.*
120 Volt – 60 Hz./1 Ph. – 1.8 amp
230 Volt – 50/60 Hz./1 Ph. – 0.6 amp
Motor Horsepower
1/10 HP
Fuse Size
15 amp maximum
Ship Weight
187 pounds
Operating Temperature
Range
40°F minimum – 110°F maximum
(4° – 43°C)
*120 Volts – 60 Hz. – 1.8 amp (U.S. Standard) (Eight foot cord with plug is included with
the U.S. Standard unit)
GROUNDING INSTRUCTIONS
n
Warning
The dispenser must be grounded in accordance with
national and local electrical codes.
This appliance must be grounded. In the event of
malfunction or breakdown, grounding provides a path of
least resistance for electric current to reduce the risk of
electric shock. This appliance is equipped with a cord having
an equipment-grounding conductor and a grounding plug.
The plug must be plugged into an appropriate outlet that is
properly installed and grounded in accordance with all local
codes and ordinances.
n
Warning
Improper connection of the equipment-grounding
conductor can result in a risk of electric shock. The
conductor with insulation having an outer surface that
is green with or without yellow stripes is the equipment
grounding conductor. If repair or replacement of the
cord or plug is necessary, do not connect the equipment-
grounding conductor to a live terminal. Check with a
qualified electrician or serviceman if the grounding
instructions are not completely understood, or if in doubt
as to whether the appliance is properly grounded. Do
not modify the plug provided with the appliance — if it
will not fit the outlet, have a proper outlet installed by a
qualified electrician.
Water Supply and Drains
POTABLE WATER
• Water temperature must be between 40°F (4.4°C) and
90°F (32°C).
• Water pressure must be between 20 psi (140 kPa) and
80 psi (550 kPa).
• Minimum internal diameter of tubing 3/8" (10 mm).
DRAIN CONNECTIONS
• Drain lines must have a 1.5 inch drop per 5 feet of run
(2.5 cm per meter) and must not create traps.
• The floor drain must be large enough to accommodate
drainage from all drains.
• Run separate bin and ice machine drain lines.
• Insulate drain lines to prevent condensation.
• Vent the ice machine drain to the atmosphere.
• Drain termination must have an air gap that meets local
code.