CONTROL BOARD ERRORS
The control board monitors the following:
Low water
Gear motor amperage
High pressure
Clogged drain
There are two different errors - Soft errors and hard errors.
• Soft errors can be reset by cycling power on/off.
• Hard errors can not be cleared by cycling power on/
off and must be reset by pressing the control board
reset button.
LO WATER - WATER LEVEL IS BELOW LOW WATER
SENSOR FOR MORE THAN 120 SECONDS
Soft Error
The control board stops the ice machine, energizes the
Lo Water & Service lights and leaves the water solenoid
energized. When water contacts the low water probe the
ice machine will resume ice making.
Hard Error
The water level sensor has 4 probes and the 2 longest
probes reach to the bottom of the water reservoir. When
no water is sensed on these probes within 60 seconds
of power up (or the water level sensor is disconnected
or shorted) the control board stops the ice machine and
energizes the Lo Water light. The ice machine must be
reset by pressing the control board reset button.
Summary of Contents for RF0300
Page 1: ...Part Number 000007661 11 16 R Model Flake Nugget Ice Machine Technician s Handbook ...
Page 8: ...THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 20: ...THIS PAGE INTENTIONALLY LEFT BLANK 20 Part Number 000007661 11 16 ...
Page 26: ...THIS PAGE INTENTIONALLY LEFT BLANK 26 Part Number 000007661 11 16 ...
Page 172: ...THIS PAGE INTENTIONALLY LEFT BLANK 172 Part Number 000007661 11 16 ...
Page 218: ...THIS PAGE INTENTIONALLY LEFT BLANK 218 Part Number 000007661 11 16 ...
Page 222: ...222 Part Number 000007661 11 16 RF0300 AIR COOLED Refer to Nameplate for Voltage Rating ...
Page 230: ...230 Part Number 000007661 11 16 RF1200 WATER COOLED Refer to Nameplate for Voltage Rating ...
Page 240: ...240 Part Number 000007661 11 16 Condensing Units RCU CONDENSING UNIT 1PH ...
Page 241: ...Part Number 000007661 11 16 241 RCU CONDENSING UNIT 3PH ...
Page 248: ...248 Part Number 000007661 11 16 RNS0308 AIR COOLED Refer to Nameplate for Voltage Rating ...
Page 256: ...256 Part Number 000007661 11 16 RNS1000 AIR COOLED Refer to Nameplate for Voltage Rating ...
Page 266: ...266 Part Number 000007661 11 16 RF1200 RFS1200 WATER COOLED 1 2 3 4 5 6 7 8 ...
Page 268: ...268 Part Number 000007661 11 16 RF2300 RFS2300 AIR COOLED 1 2 3 4 5 6 7 8 8 ...
Page 270: ...270 Part Number 000007661 11 16 RF2300 RFS2300 WATER COOLED 1 2 3 4 5 6 7 8 8 ...
Page 278: ...278 Part Number 000007661 11 16 RN0400 RN1000 RN1400 AIR WATER COOLED 1 2 3 4 5 6 ...
Page 282: ...THIS PAGE INTENTIONALLY LEFT BLANK 282 Part Number 000007661 11 16 ...
Page 283: ......