![Manitowoc RF0300 Technician'S Handbook Download Page 108](http://html.mh-extra.com/html/manitowoc/rf0300/rf0300_technicians-handbook_701084108.webp)
108
RF2300C/RFS2300C Troubleshooting
QUIETQUBE REMOTE AIR-COOLED MODELS WITH
REMOTE CONDENSING UNIT
Normal Operation
When the toggle switch is placed in the ON position the
following controls must be in the closed position before
the ice machine will start:
A. Bin Thermostat
B. High Pressure Cut-out Switch
C. Ice Chute Safety Switch
D. Low Pressure Switch
E. Low Water Level Switch
Placing the toggle switch in the ON position starts the
gear motor. After the rotation speed sensor verifies 10
minutes of correct rotation the time delay ends and the
liquid line solenoid valve opens.
• When the refrigerant pressure is high enough to close
the low-pressure control the contactor coil energizes
and the compressor starts.
• The refrigerant pressure will increase and close the
fan cycling pressure control and the condenser fan
motor starts.
The ice machine will continue to make ice until ice
contacts the bin thermostat and the liquid line solenoid
valve closes and the refrigeration system pumps down.
• The refrigerant pressure drops and the fan cycling
pressure control opens stopping the condenser fan
motor.
• When the refrigerant pressure is low enough to open
the low pressure control, the contactor coil is de-
energized and the compressor stops.
NOTE: The ice machine remains off until ice no longer
contacts the bin thermostat.
Summary of Contents for RF0300
Page 1: ...Part Number 000007661 11 16 R Model Flake Nugget Ice Machine Technician s Handbook ...
Page 8: ...THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 20: ...THIS PAGE INTENTIONALLY LEFT BLANK 20 Part Number 000007661 11 16 ...
Page 26: ...THIS PAGE INTENTIONALLY LEFT BLANK 26 Part Number 000007661 11 16 ...
Page 172: ...THIS PAGE INTENTIONALLY LEFT BLANK 172 Part Number 000007661 11 16 ...
Page 218: ...THIS PAGE INTENTIONALLY LEFT BLANK 218 Part Number 000007661 11 16 ...
Page 222: ...222 Part Number 000007661 11 16 RF0300 AIR COOLED Refer to Nameplate for Voltage Rating ...
Page 230: ...230 Part Number 000007661 11 16 RF1200 WATER COOLED Refer to Nameplate for Voltage Rating ...
Page 240: ...240 Part Number 000007661 11 16 Condensing Units RCU CONDENSING UNIT 1PH ...
Page 241: ...Part Number 000007661 11 16 241 RCU CONDENSING UNIT 3PH ...
Page 248: ...248 Part Number 000007661 11 16 RNS0308 AIR COOLED Refer to Nameplate for Voltage Rating ...
Page 256: ...256 Part Number 000007661 11 16 RNS1000 AIR COOLED Refer to Nameplate for Voltage Rating ...
Page 266: ...266 Part Number 000007661 11 16 RF1200 RFS1200 WATER COOLED 1 2 3 4 5 6 7 8 ...
Page 268: ...268 Part Number 000007661 11 16 RF2300 RFS2300 AIR COOLED 1 2 3 4 5 6 7 8 8 ...
Page 270: ...270 Part Number 000007661 11 16 RF2300 RFS2300 WATER COOLED 1 2 3 4 5 6 7 8 8 ...
Page 278: ...278 Part Number 000007661 11 16 RN0400 RN1000 RN1400 AIR WATER COOLED 1 2 3 4 5 6 ...
Page 282: ...THIS PAGE INTENTIONALLY LEFT BLANK 282 Part Number 000007661 11 16 ...
Page 283: ......