105
WATER SYSTEM CHECKLIST
A water-related problem often causes the same
symptoms as a refrigeration system component
malfunction.
Example: A water dump valve leaking during the
freeze cycle, a system low on charge, and a starving
TXV have similar symptoms.
Water system problems must be identified and
eliminated prior to replacing refrigeration components.
Water area (evaporator) is dirty
•
Clean as needed
Water inlet pressure not between 20 and 80 psig
(1–5 bar, 138–552 kPa)
•
Install a water regulator valve or increase the
water pressure
Incoming water temperature is not between 35°F
(1.7°C) and 90°F (32.2°C)
•
If too hot, check the hot water line check valves in
other store equipment
Water filtration is plugged (if used)
•
Install a new water filter
Vent tube is not installed on water outlet drain
•
See Installation Instructions
Hoses, fittings, etc., are leaking water
•
Repair/replace as needed
Water float valve is stuck open or closed
•
Clean/replace as needed
Water is spraying out of the sump trough area
•
Stop the water spray
Uneven water flow across the evaporator
•
Clean the ice machine
Water is freezing behind the evaporator
•
Correct the water flow
Plastic extrusions and gaskets are not secured to
the evaporator
•
Remount/replace as needed
Summary of Contents for Q130 series
Page 2: ......
Page 16: ...16 Part Number 8001119 10 19 SM50 MODEL SERIAL NUMBER PLATE ...
Page 36: ...36 Part Number 8001119 10 19 This Page Intentionally Left Blank ...
Page 98: ...98 Part Number 8001119 10 19 This Page Intentionally Left Blank ...
Page 202: ...202 Part Number 8001119 10 19 This Page Intentionally Left Blank ...
Page 234: ...234 Part Number 8001119 10 19 This Page Intentionally Left Blank ...
Page 235: ......