2-37
600E2 OPERATOR MANUAL
SAFETY PRECAUTIONS
2
Table 2-9 Boom Drift Chart (Cylinder length change in millimeters)
OVERLOAD INSPECTION
This information supplements the Rated Capacity Limiter
(RCL) manual supplied with each National Crane.
When the RCL system has acknowledged an overload on
your crane, you must carry out specified inspections on the
crane.
These inspections apply only to overloads up to 50%. For
overloads of 50% or higher, crane operation must be
stopped immediately and Crane Care must be contacted for
corrective action.
T h e f o l l o w i n g i l l u s t r a t i o n s m a y n o t b e a n e x a c t
representation of your crane and are to be used for reference
only.
NOTE:
If your crane is equipped with CraneSTAR, an
overload warning will be posted to the web site for
review by the crane owner.
Overload warnings do NOT indicate real time
events! Warnings could be sent 24 hours (or more)
after the actual event.
Coeff. = 0.000774 (1/ °C)
STROKE
Temperature Change (°C)
(m)
5
10
15
20
25
30
35
40
45
50
55
1.5
6
12
17
23
29
35
41
46
52
58
64
3
12
23
35
46
58
70
81
93
104
116
128
4.5
17
35
52
70
87
104
122
139
157
174
192
6
23
46
70
93
116
139
163
186
209
232
255
7.5
29
58
87
116
145
174
203
232
261
290
319
9
35
70
104
139
174
209
244
279
313
348
383
10.5
41
81
122
163
203
244
284
325
366
406
447
12
46
93
139
186
232
279
325
372
418
464
511
13.5
52
104
157
209
261
313
366
418
470
522
575
15
58
116
174
232
290
348
406
464
522
581
639
16.5
64
128
192
255
319
383
447
511
575
639
702
18
70
139
209
279
348
418
488
557
627
697
766
Length change in mm = Stroke (m) X Temperature Change ( °C) X Coeff. (1/ °C) X 1000 mm/m
M etric
WARNING
Overload Hazard!
To avoid an accident caused by overload damage to your
crane:
•
Perform the inspections outlined in this publication
for overloads up to 50%.
•
Stop operating the crane and contact Manitowoc
Crane Care immediately for overloads of 50% and
higher.
Fo
r
Reference
Only
Summary of Contents for National Crane 600E-2
Page 1: ...Operator Manual National Crane 600E 2 F o r R e f e r e n c e O n l y ...
Page 2: ...F o r R e f e r e n c e O n l y ...
Page 10: ...TOC 6 TABLE OF CONTENTS OPERATOR MANUAL 600E2 THIS PAGE BLANK F o r R e f e r e n c e O n l y ...
Page 121: ...F o r R e f e r e n c e O n l y ...
Page 122: ...F o r R e f e r e n c e O n l y ...