78
Beermaster Blenders
N
2
/CO
2
BLENDER (SINGLE — 00520182, DUAL —
00520183)
Installing
1. Decide where the N
2
/CO
2
Blender Kit will be
mounted.
NOTE: Be sure the panel is on a wall in a well
ventilated, accessible indoor area that is out of harm’s
way.
2. Mount the panel on the wall.
3. Hook-up panel using thread sealant on threads
and a back-up wrench on panel fittings.
NOTE: Do not use fittings with check valve on inlets.
Do not remove 1/4" female threaded fittings from
panel, as they contain filters.
4. Test all fittings for leaks.
5. Use regulators and tubing suitable for 70 –
150 PSI.
NOTE: Regulators set at 50 PSI are suitable on a
50 PSI blender.
6. Secure all cylinders to the wall.
NOTE: Store cylinders in a well ventilated, accessible
area.
Outlet for Mixed Gas
(most beers)
Outlet for Mixed Gas
(Guiness)
Secondary
Regulators
Use
reinforced
tubing
suitable for
70-150 PSI
Primary CO
2
Regulator
Primary N
2
Regulator
Use
reinforced
tubing
suitable for
70-150 PSI
Secondary
Regulators
N
2
Tank
CO
2
Tank
STH13_Tech.book Page 78 Wednesday, September 15, 2010 3:20 PM