ETC Error Codes
Pressure
Beer runs with
streaks.
System may be under
restricted. Add additional
restriction to system by
adding additional 3/16" I.D.
vinyl tubing to the faucet
end of the system.
Beer draws great
during slow time of
day but turns to all
foam during peak
sale periods.
See above. Check
regulator for proper
operation. Check primary
regulator to see if it allows
enough CO
2
for secondary
regulators. Check walk-in
cooler temperature is 38°F
(3.3°C) or less.
Off-taste
Beer is flat.
Adjust air blender by
increasing CO
2
in blend
and decreasing air in
blend. Or there is no
Air/CO
2
blender.
Beer has off-taste
(bitter or “skunky”).
Change air intake filters.
Check for moisture in air
tank. Clean system. Check
air intake supply. Check air
filter and trap. Ensure
proper rotation of kegs in
series. Check cleaning
schedule for beer lines.
Fault Code
Definition
Solution
SF flashing
alternately with OP
sensor
Open temperature
sensor or sensor wiring.
Check sensor wiring. Turn
wiring power OFF and ON
to reset control. Replace
sensor.
SF flashing
alternately with SH
Shorted temperature
sensor or sensor wiring
Check sensor wiring. Turn
wiring power OFF and ON
to reset control. Replace
sensor.
EE
Program failure
Reset control by pressing
the Menu button. If
problems persist, replace
the control.
Problem
Possible Cause
To Correct