![Manitowoc MLC650 Service Maintenance Manual Download Page 364](http://html.mh-extra.com/html/manitowoc/mlc650/mlc650_service-maintenance-manual_701260364.webp)
Reference
Only
ACCESSORIES
MLC650 SERVICE/MAINTENANCE MANUAL
10-66
Published 09-09-16, Control # 229-09
VPC-MAX On Hook Limit Switch Adjustment
The VPC-MAX on hook limit switches require adjustment.
On Hook Switch Adjustment
for the following.
1.
Set the adjustable limit switch arm to 56 mm (2 in).
2.
Set the switch to trip when the beam hook is 6 mm (0.24
in) away from contacting the pin on the rear of the
rotating bed.
3.
The free state of the adjustable arm (4) is 60°, and the
tripped state of the arm is 34°.
Item Description
1
Beam Up Limit Switch
2
VPC-MAX Beam
3
Rotating Bed
4
On Hook Limit Switch Adjustable Arm
5
Switch Mount Bracket
6
On Hook Limit Switch
7
56 mm
FIGURE 10-53