156
SY
MPT
OM
#
3 SELF-C
ONT
AINED
AIR
OR
W
ATER-C
OOLED
YES
YES
YES
NO
NO
NO
YES
Ice Machine Will Not Harvest - Freeze Cycle is Normal and Ice Cubes are Not Melted
After Harvest
Low production,
Normal fill pattern, long
harvest cycle, Possible SL #2
,
Back of cubes are not melte
d
Discharge line temperature is greater than
150°F at the end of the freeze cycle?
Refer to
Symptom #2 Freeze Cycle Operationa
l
Analysis Tabl
e
Is harvest valve energized
?
Refer to Sequence of
Operation &
Wiring Diagram
s
Is head pressure high
&
suction pressure low
in harvest?
(Refer to Pressure Charts)
Replace harvest
valve
ST
AR
T
Summary of Contents for Indigo ID0302A
Page 2: ......
Page 20: ...20 Part Number STH025 11 16 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 36: ...36 Part Number STH025 11 16 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 162: ...162 Part Number STH025 11 16 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 212: ...212 Part Number STH025 11 16 ACCESS REMOTE RECOVERY EVACUATION CONNECTIONS ...
Page 224: ...224 Part Number STH025 11 16 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 266: ...266 Part Number STH025 11 16 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 269: ...Part Number STH025 11 16 269 I0320 1PH AIR WATER Self Contained Air Water cooled ...
Page 270: ...270 Part Number STH025 11 16 I0500 1PH REMOTE Remote Air cooled 000007405_06 ...
Page 277: ...Part Number STH025 11 16 277 I1400 II1406 1800 1PH REMOTE Remote Condenser 000008864_04 ...
Page 278: ...278 Part Number STH025 11 16 I1400 I1406 I1800 3PH REMOTE Remote Condenser 000008864_04 ...
Page 288: ...288 Part Number STH025 11 16 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 289: ...Part Number STH025 11 16 289 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 290: ......
Page 291: ......
Page 292: ......
Page 293: ......
Page 294: ......
Page 295: ......