![Manitowoc Grove TMS9000-2 Series Service Manual Download Page 244](http://html.mh-extra.com/html/manitowoc/grove-tms9000-2-series/grove-tms9000-2-series_service-manual_701234244.webp)
7-12
Published 01-14-2021 Control # 707-01
POWER TRAIN
TMS9000-2 SERVICE MANUAL
6.
Attach the crane’s sensor harness wires, as tagged
during removal, to the sensor wire leads of the system.
7.
Attach the tubing as tagged during removal.
8.
Secure all wiring and tubing to prevent damage from
heat and abrasion.
9.
As needed, install a replacement exhaust wrap around
the exhaust tube.
10.
Install exhaust system guards and secure with
capscrews, lock washers, flat washers, and nuts.
Slip Joint Exhaust Connectors
Slip joint exhaust couplers require tightening to avoid
exhaust leaks. Perform the following procedures at the
appropriate intervals.
After 1000 Hours or One Year
Visually inspect the exhaust connector. If necessary, tighten
the v-clamps by one full turn of the nuts.
2000 Hours or 2 Years
Tighten the v-clamps by 1 ½ turns of the nuts.
4000 Hours or 4 Years
Tighten the v-clamp by 1 ½ turns of the nuts.
5000 Hours or 5 Years
Remove the v-clamps and gaskets, and replace them with
new gaskets and clamps. Tighten the v-clamps to 9.6 to 11.3
Nm (85 to 100 lb-in) of torque.
Exhaust System
8967-1
2
1
1.
Single Module Aftertreatment
2.
Diesel Exhaust Fluid (DEF) Injector
FIGURE 7-9
Fo
r
Reference
Only