Instructions

Manitowoc Beverage Systems Sellersburg, 

2100 Future Drive, Sellersburg, IN 47172, Tel: 812-246-7000, www.manitowocbeverage.com

5031227 REV 2

5/12

Subject: 464 Flow Control Base Kit (5031061)

This kit was developed to replace, and correct leaking flow controls on the 454 and 
464 series valves. Please follow these instructions for installation of this kit.

Steps for Replacement:

1  Turn power off to valves by turning key switch to the off position.
2  Remove the cover from leaking valve.
3  Unplug the low voltage connection from valve. (See Figure 1)
4  Turn water and syrup off by turning the valve shutoffs on the Back Block to the off 

position. (See Figure 2)

5  Remove the valve from unit by pulling the Latch pin up then pulling the valve toward 

you. (See Figure 3)

Once the valve is removed from the unit all valve components must be removed from the 
existing flow control base. Save all components removed from valve for reassembly unless 
otherwise noted.

6  Remove the four screws from the front of the valve that secure the Diffuser block and 

the Solenoid Coil Assembly. (See Figure 4)

7  Remove the Diffuser block and Solenoid Coil Assembly from valve.
8  Remove the two screws that secure the Pallet Retainer Spring and/or Orifice caps to the 

flow control base. (See Figure 5)

9  Remove the Pallet Retainer Spring (if used), both Orifice Caps, and Pallets from the flow 

control base. (See Figure 6)

10  Remove the Pivot Pin, and Coil spring (if used) from Flow Control Base. (See Figure 7)

464 Flow Control Base Kit 5031061

Part #

Description

Qty

020001284

Screw 8 x 5/8 PH

3

61004

Retainer Plate

1

64300

464-GP Flow Rate 

Adjustment

2

5028273

O-Ring

2

60047G

464 Flow Control 

Base

1

FIGURE 1

FIGURE 2

FIGURE 3

Unplug

FIGURE 4

SCREWS

SCREWS

SCREWS

FIGURE 5

Pallet

Orifice Cap

FIGURE 6

FIGURE 7

Coil Spring

Pivot Pin