![Manitowoc 999 Service And Maintenance Manual Download Page 291](http://html.mh-extra.com/html/manitowoc/999/999_service-and-maintenance-manual_701168291.webp)
Reference
Only
Manitowoc
Published 05-16-17, Control # 233-03
10-55
999 SERVICE/MAINTENANCE MANUAL
TROUBLESHOOTING
10
Test 23 – Servicing the Motor Loop Flushing (Purge) Valves
Problems with a faulty loop-flushing valve are best corrected
by replacing the complete valve assembly. To service the
loop flushing valve:
•
Engine must be off and power off, with all brakes and
locks engaged.
•
Drain motor by removing attached hydraulic lines.
•
After draining, replace hydraulic hose.
•
Remove hoses from flushing valve and replace valve.
•
The hydraulic fluid flow through the valve is adjusted with
valve flow control on top of valve (set for 6 gpm).
•
The hydraulic sequence valve is adjusted with flow
control on side of valve (set for 200 psi [14 bar]).
Item
Description
1
Motor
2
Loop Flushing (purge) Valve
3
Valve Flow Control
4
Sequence Valve
P1603
3
1
4
2