Master Node Pin Identification
Master Node installed on Cranestar equipped and Tier 4.
Pin #
Function Type
Description
Test Voltage
(DC unless otherwise specified)
P11
Receptacle – Front Console Master Node (Unused Terminals are Omitted)
P11-01
24 Volts
24VDC Power Bus
24 Volts Nominal
P11-03
DI-12
Load Indicator Scroll Up Switch
0 Volts Off; 24 Volts On
P11-04
DI-14
Load Indicator Scroll Down Switch
0 Volts Off; 24 Volts On
P11-05
DI-31
Load Indicator Select Switch
0 Volts Off; 24 Volts On
P11-06
DI-9
Load Indicator Confirm Switch
0 Volts Off; 24 Volts On
P11-08
DO-3
Load Indicator Warning LED
0 Volts Off; 24 Volts On
P11-09
DO-8
Beacon Alarm
0 Volts Off; 24 Volts On
P11-10
DO-6
Load Indicator Caution LED
0 Volts Off; 24 Volts On
P11-11
24 Volts
24VDC Power Bus
24 Volts Nominal
P11-18
DO-4
System Fault Beeper Alarm
0 Volts Off; 24 Volts On
P11-19
DO-7
Load Indicator Operator Cab Alarm
0 Volts Off; 24 Volts On
P11-20
DO-5
Operating Limit Buzzer
0 Volts Off; 24 Volts On
P11-27
DO-1Grd
CAN System Ground
Ground
P11-28
DO-2 Grd
CAN System Ground
Ground
P11-30
DO-4 Grd
CAN System Ground
Ground
P11-31
CANH
CAN-Hi Data Line
N/A
P11-32
CANL
CAN-Low Data Line
N/A
P11-37
DO-5 Grd
CAN System Ground
Ground
P12
Receptacle – Front Console Master Node (Unused Terminals are Omitted)
P12-01
24 Volts
24VDC Power Bus
24 Volts Nominal
P12-02
Display
Screen Contrast Positive
N/A
P12-06
DI-2
Data Logger Enable
0 Volts Off; 24 Volts On
P12-07
DO-9
High Exhaust System Temperature Amber LED
0 Volts Off; 24 Volts On
P12-08
DO-11
Rear Drum 2 Free Fall Amber LED
0 Volts Off; 24 Volts On
P12-09
DO-16
Operating Limit Amber LED
0 Volts Off; 24 Volts On
P12-10
DO-14
Diesel Particulate Filter Amber LED
0 Volts Off; 24 Volts On
P12-11
24 Volts
24VDC Power Bus
24 Volts Nominal
P12-12
Display
Screen Contrast Wiper Adjust
N/A
P12-17
DO-10
Front Drum 1 Free Fall Amber LED
0 Volts Off; 24 Volts On
P12-19
DO-15
System Fault Red LED
0 Volts Off; 24 Volts On
P12-20
DO-13
DPF Regen Disable (Inhibit) Amber LED
0 Volts Off; 24 Volts On
P12-21
Logic Grd
CAN System Ground
Ground
P12-22
Display
Screen Contrast Negative
N/A
P12-27
DO-9 Grd
CAN System Ground
Ground
P12-28
DO-10 Grd
CAN System Ground
Ground
P12-29
DO-11 Grd
CAN System Ground
Ground
P12-31
CANH
CAN-Hi Data Line (CraneSTAR)
N/A
P12-32
CANL
CAN-Low Data Line (CraneSTAR)
N/A
P12-33
DI-19
DPF Regen Switch ON (initiate)
0 Volts Off; 24 Volts On
Summary of Contents for 999
Page 1: ...R e f e r e n c e O n l y Service Maintenance Manual Manitowoc 999 ...
Page 2: ...R e f e r e n c e O n l y ...
Page 4: ...R e f e r e n c e O n l y THE ORIGINAL LANGUAGE OF THIS PUBLICATION IS ENGLISH ...
Page 297: ...R e f e r e n c e O n l y ...
Page 298: ...R e f e r e n c e O n l y ...