Reference
Only
Manitowoc
Published 12-05-17, Control # 035-23
3-45
18000 SERIVCE/MAINTENANCE MANUAL
ELECTRIC SYSTEM
3
To determine a state of an individual digital input or output,
find the individual crane component in
or
, for example: Return Filter Alarm
CAN38-1-32
.
•
The first part of the Code Number
CAN38
indicates that
the individual input or output is located in packet
38
of
the master CAN computer.
NOTE 1:
If the Code Number starts with FCN, see FCN
screen for the input/output.
•
Select PACKET ID#
38
by moving select/confirm switch
to SELECT and a cursor appears next to Packet ID #.
Scroll up or down to desired packet number to display
packet item status.
•
The second part of Code Number
1
is
bank
were the
individual information is shown on the CAN screen.
•
The third part of the Code Number
32
is the item
identifier
.
To determine the state of the individual input/output in a
bank, find the number displayed for the bank in the
numbered column of
. In the corresponding row
the identifier numbers that are ON (active) in the bank are
shaded. In the above example if
32
is shaded the Return
Filter Alarm is ON (active).
To exit CAN screen move select/confirm switch to SELECT
and cursor disappears. Continue scrolling up or down to
access next screen.
Hydraulic System Calibration
See Hydraulic System Calibration Procedures in this section.
Speed/Torque
See Function Speed/Torque Adjustment in this section.
Accessory System
The ACC system screen displays the following information:
•
Drum 5 (mast hoist) control HANDLE command in
percent from neutral with + raise and - lower.
•
Accessory valve (ACC VLV) command in percent.
•
Drum 5 (mast hoist) pump (DM 5 PMP) command in
percent from neutral with + raise and - lower.
•
Accessory system pressure (ACC PRES) in psi.
•
Drum 5 (mast hoist) pump pressure (DM 5 PRES) in psi.
•
Drum 5 (mast hoist) drum speed (DM 5 SPD) in rpm.
•
Accumulator system pressure (ACCUM PRES) in psi.
•
VALVES - displays binary number of system
components that are active in bank:
Bank 1:
1 = Jacking command.
2 = Rotating fame command.
4 = Mast raise switch and mast hoist control handle
command is OFF.
8 = Mast lower switch and mast hoist control handle
command is OFF
16 = Boom hinge pins in switch.
32 = Boom hinge pins out switch.
64 = Mast pins in switch.
128 = Mast pins out switch.
256 = Cab tilt up.
512 = Cab tilt down.
1028 = Raise mast arms from stored position.
2056 = Lower mast arms to stored position.
4096 = MAX-ER cylinder.
8192 = Rigging winch command.
PRESSURE SENDER CAL
CONTROL CAL
PUMP PRESSURE TEST
CHARGE PRESSURE
0%
0%
0%
0
0
0
0
0
0
DRUM 1 SPEED
DRUM 2 SPEED
DRUM 3 SPEED
DRUM 4 SPEED
25 %
50 %
25 %
25 %
DRUM 6 SPEED
TRAVEL SPEED
SWING SPEED
SWING TORQUE
25 %
75 %
25 %
60 %
HANDLE
ACC VLV
DM 5 PMP
VALVES
+/-0 %
-0 %
+/-0 %
256
ACC PRES
DM 5 PRES
DM 5 SPD
ACCUM P
psi
psi
rpm
psi
ACC
Summary of Contents for 18000
Page 1: ...R e f e r e n c e O n l y Service Maintenance Manual Manitowoc 18000 ...
Page 2: ...R e f e r e n c e O n l y ...
Page 4: ...R e f e r e n c e O n l y THE ORIGINAL LANGUAGE OF THIS PUBLICATION IS ENGLISH ...
Page 210: ...R e f e r e n c e O n l y NOTES SKETCHES AND PHOTOGRAPHS ...
Page 315: ...R e f e r e n c e O n l y ...