Reference
Only
ELECTRIC SYSTEM
18000 SERIVCE/MAINTENANCE MANUAL
3-26
Published 12-05-17, Control # 035-23
NODE 20 - Boom Block Up, Block Sensor, & Limits
Reference Electrical Schematic A06374 - Sheets 14 and 22
.
Can ID. No.
Function
Type
Description
Test Voltage
Packet No.
J1
Receptacle – Can In
201-A
24 Volts
Can Bus System (From RCL Receiver)
24 Volts Nominal
201-B
AI-NS
Node Select AI-NS
Node Select Jumper to Ground
201-C
CANH
Can High Wire Transmission (From RCL Receiver) N/A
201-D
Ground
Can System Bus (From RCL Receiver)
Ground
201-E
Ground
Node Select Ground
Jumper to AI-NS
201-F
CANL
Can Low Wire Transmission (From RCL Receiver) N/A
J2
Receptacle – Upper Block Up
202-A
24 Volts
Block Up Limit Boom Upper Point
24 Volts Nominal
202-B
DI-2
Block Up Limit Boom Upper Point
0 Volts Off; 24 Volts On
CAN136-6-128
J3
Receptacle – Lower Block Up
203-A
24 Volts
Block Up Limit Boom Lower Point
24 Volts Nominal
203-B
DI-1
Block Up Limit Boom Lower Point
0 Volts Off; 24 Volts On
CAN136-6-64
J4
Receptacle – Can Out
204-A
24 Volts
Can Bus System
24 Volts Nominal
204-C
CANH
Can High Wire Transmission
N/A
204-D
Ground
Can System Bus
Ground
204-E
DI-ID
To Jib Butt Cable Reel
24 Volts Nominal
CAN 136-6-4
204-F
CANL
Can Low Wire Transmission
N/A
J5
Receptacle – Block Level Sensor
205-A
24 Volts
Load Pin 1 - Lower Boom Point
24 Volts Nominal
205-B
AI-1
Load Pin 1 - Lower Boom Point
0.47 V No Load; 5.7 V Full Load
205-D
Ground
Load Pin 1 - Lower Boom Point
Ground
J6
Receptacle – Block Level Sensor
206-A
24 Volts
Load Pin 2 - Lower Boom Point W/Tandem Drum
24 Volts Nominal
206-B
AI-2
Load Pin 2 - Lower Boom Point W/Tandem Drum
0.47 V No Load; 5.7 V Full Load
206-D
Ground
Load Pin 2 - Lower Boom Point W/Tandem Drum
Ground
J8
Wind Speed Indicator
208-A
AI-3
Wind Speed Sensor
0.05 to 16 Volts DC
208-B
Ground
Wind Speed Sensor
Ground
J9
Receptacle – Maximum Jib Angle Limit
209-A
24 Volts
Maximum Jib Angle Limit
24 Volts Nominal
209-B
DI-6
Maximum Jib Angle Limit
0 Volts Off; 24 Volts On
CAN136-6-32
J10
Receptacle – Maximum Jib Angle Working Limit
2010-A
24 Volts
Maximum Jib Angle Working Limit
24 Volts Nominal
2010-B
DI-5
Maximum Jib Angle Working Limit
0 Volts Off; 24 Volts On
CAN136-6-16
J11
Receptacle – Minimum Jib Angle Limit
2011-A
24 Volts
Minimum Jib Angle Limit
24 Volts Nominal
2011-B
DI-4
Minimum Jib Angle Limit
0 Volts Off; 24 Volts On
CAN136-6-8
Boom Angle Indicator
Wire 1
5 Volts
Boom Angle Indicator
5 Volts Nominal
Wire 2
Signal
Boom Angle Indicator
Between 0 and 5 Volts
Wire 3
Ground
Boom Angle Indicator
Ground
Summary of Contents for 18000
Page 1: ...R e f e r e n c e O n l y Service Maintenance Manual Manitowoc 18000 ...
Page 2: ...R e f e r e n c e O n l y ...
Page 4: ...R e f e r e n c e O n l y THE ORIGINAL LANGUAGE OF THIS PUBLICATION IS ENGLISH ...
Page 210: ...R e f e r e n c e O n l y NOTES SKETCHES AND PHOTOGRAPHS ...
Page 315: ...R e f e r e n c e O n l y ...
Page 316: ...R e f e r e n c e O n l y ...