Published 12-05-17, Control # 035-23
NODE 8 - Drum 1 and Drum 6
Reference Electrical Schematic A06374 - Sheets 12, 19 and 21
.
Can ID. No.
Function
Type
Description
Test Voltage
Packet No.
WN18-A/WN12-A
24 Volts
From Node 7 to Bin Node
24 Volts Nominal
WN18-C/WN12-C
CANH
Can High Wire Transmission
N/A
WN18-D/WN12-D
Ground
From Node 7 to Bin Node
Ground
WN18-F/WN12-F
CANL
Can Low Wire Transmission
N/A
J4
Receptacle – Drum 6 Controls
84-A
Ground
Drum 6 Motor Control
Ground
84-B
DO-11
Drum 6 Motor Control
for Values
CAN39-2-4
84-C
Ground
Drum 6 Brake Solenoid
Ground
84-D
DO-12
Drum 6 Brake Solenoid
0 Volts Off; 24 Volts On
CAN39-2-8
84-F
DO-13
Drum 6 Pawl In Motor
0 Volts Off, 24 Volts On
CAN39-2-16
84-G
Ground
Drum 6 Pawl Motor
Ground
84-H
DO-14
Drum 6 Pawl Out Motor
0 Volts Off; 24 Volts On
CAN39-2-32
84-g
Ground
Jumper to Node Select 1
Ground
84-h
NS-1
Node Select 1 Jumper to Ground
0 Volts (With Jumper)
84-m
NS-4
Node Select 4 Jumper to Ground
0 Volts (With Jumper)
84-r
Ground
Juniper to Node Select 4
Ground
J6
Receptacle – Drum 1 Controls
86-A
Ground
Drum 1 Motor Control 1
Ground
86-B
DO-7
Drum 1 Motor Control 1
for Values
CAN39-1-64
86-C
Ground
Drum 1 Motor Control 2
Ground
86-D
DO-8
Drum 1 Motor Control 2
for Values
CAN39-1-128
86-E
Ground
Drum 1 Brake Solenoid
Ground
86-F
DO-9
Drum 1 Brake Solenoid
0 Volts Off; 24 Volts On
CAN39-2-1
86-G
Ground
Drum 1 Minimum Bail Limit Switch
Ground
86-H
DO-10
Drum 1 Minimum Bail Limit Switch
0 Volts Off; 24 Volts On
CAN39-2-2
86-J
DI-8
Drum 1 Minimum Bail Limit Switch
0 Volts Off; 24 Volts On
CAN71-1-128
86-K
NS-1
Node Select 1 Jumper to Ground
0 Volts (With Jumper)
86-N
NS-4
Node Select 4 Jumper to Ground
0 Volts (With Jumper)
86-U
Ground
Jumper to Node Select 4
Ground
86-V
5 Volts
Drum 1 and Drum 6 Motor Speed Sensor
5 Volts DC
86-W
Ground
Jumper to Node Select 1
Ground
86-Z
Ground
Drum 1 Motor Speed Sensor
Ground
86-j
Ground
Drum 6 Motor Speed Sensor
Ground
86-n
ENC-1A
Drum 1 Motor Speed Sensor CH A
1.2 or 3.2 Volts Not Moving;
2.2 Volts Moving
CAN70-2
2
86-p
ENC-1B
Drum 1 Motor Speed Sensor CH B
1.2 or 3.2 Volts Not Moving;
2.2 Volts Moving
CAN70-2
2
86-r
ENC-2A
Drum 6 Motor Speed Sensor CH A
1.2 or 3.2 Volts Not Moving;
2.2 Volts Moving
CAN70-4
2
86-s
ENC-2B
Drum 6 Motor Speed Sensor CH B
1.2 or 3.2 Volts Not Moving;
2.2 Volts Moving
CAN70-4
2
2
– The number in the indicated bank should increase with device rotation and decrease with rotation in opposite direction.
Summary of Contents for 18000
Page 1: ...R e f e r e n c e O n l y Service Maintenance Manual Manitowoc 18000 ...
Page 2: ...R e f e r e n c e O n l y ...
Page 4: ...R e f e r e n c e O n l y THE ORIGINAL LANGUAGE OF THIS PUBLICATION IS ENGLISH ...
Page 210: ...R e f e r e n c e O n l y NOTES SKETCHES AND PHOTOGRAPHS ...
Page 315: ...R e f e r e n c e O n l y ...
Page 316: ...R e f e r e n c e O n l y ...