Install Signal Cable
4.4.1
Standard Series Press
The flash cure is designed to receive operational signals either from the M&R press PLC or
from an independent remote sensor located under the index table assembly.
WARNING:
Ensure none of the pallets are positioned under the flash cure for an excessive
time while the flash cure is on. Extreme heat can damage pallets, garments and/or cause a
fire.
Step 1
Install the signal cable from the socket (1) marked
PLC/SENSOR SIGNAL
on the flash cure to the
plug socket (2) located on the lower electrical
enclosure of the press. The remaining plugs are
provided for installation of additional flash cure
systems.
Step 2
Press the
F4
key twice to select the mode of
operation for the flash cure, PLC mode or
Proximity mode. The control displays
MODE
on
the upper line, and either
PRX
or
PLC
on the
lower line indicating which mode is currently
selected. Press the arrow keys to change the
mode.
Note: In
PLC
mode, the flash cure receives its start
signal from the PLC on the press. In
PRX
mode,
the flash cure receives its start signal from the
floor stand mounted proximity switch.