Ref.: WB-VL-SM Ver.1 3.doc
23
Move the Distance/Diameter measuring rod & touch the inner plane profile of the Rim
properly and hold it for 3 seconds until Audio indication and then move the
Distance/Diameter measuring rod to its home position.
Fig. 41
Press
key to save the Diameter calibration values. “
Dia calibration saved and
completed
” message will be displayed briefly.
Mount a Wheel & ensure the Rim diameter measured in
RIM PARAMETERS
screen is
as per the Wheel Diameter specifications within tolerance li
mit of ±0.3”.
4.3.
WIDTH CALIBRATION
(Applicable only for Premium model)
For recording the Zero position accurately, Width rod should be rested on the
Stopper position and also 90° in X axis at the same time
Use navigation keys to select
WIDTH CALIBRATION
& press
key. Following
screen will be displayed:
Fig. 42
Keep the Width measuring rod in zero position (ie. Stopper Position) and ensure the
displayed Width voltage & Outer Dia voltage is 1.00V±0.1V & 2.50V±0.1V respectively.
If the displayed Outer dia voltage is not within specification, move the Width
assembly to make it perpendicular with the cabinet and touch it with the
stoppers. Now loosen the Grub screws to rotate the outer dia shaft for
achieving the required voltage and tighten the screws in that position
If the displayed Width voltage is not within specification, move the Width
assembly to make it perpendicular with the cabinet and touch it with the
stoppers. Now loosen the Allen screws available at the rear side of Width
board housing and take out the Width measurement pipe. Now adjust the shaft
in the Width board for achieving the required voltage. Fix the Width
measurement pipe by ensuring perpendicularity
1.
If Width rod is either not in its zero position properly or the Width/Outer Dia
voltage is not within specifications and
key is pressed,
”Width rod in
Zero position” message will be displayed
Summary of Contents for LX WB-VL-65 DSP
Page 48: ...Ref WB VL SM Ver 1 3 doc 45 7 DIAGRAMS 7 1 BLOCK DIAGRAM 7 1 1 LCV MODELS Fig 99...
Page 49: ...Ref WB VL SM Ver 1 3 doc 46 7 1 2 HCV MODEL THREE PHASE OPERATION Fig 100...
Page 50: ...Ref WB VL SM Ver 1 3 doc 47 SINGLE PHASE OPERATION Fig 101...
Page 51: ...Ref WB VL SM Ver 1 3 doc 48 7 2 WIRING DIAGRAM 7 2 1 LCV MODELS Fig 102 1 of 3...
Page 52: ...Ref WB VL SM Ver 1 3 doc 49 Fig 102 2 of 3...
Page 53: ...Ref WB VL SM Ver 1 3 doc 50 Fig 102 3 of 3...
Page 54: ...Ref WB VL SM Ver 1 3 doc 51 7 2 2 HCV MODEL THREE PHASE OPERATION Fig 103 1 of 3...
Page 55: ...Ref WB VL SM Ver 1 3 doc 52 Fig 103 2 of 3...
Page 56: ...Ref WB VL SM Ver 1 3 doc 53 SINGLE PHASE OPERATION Fig 103 3 of 3...