This addendum is to be used in conjunction with the Installation & Instruction Manual.

Commercial & Industrial 

Commercial & Industrial 

High-Speed 

High-Speed 

Heavy-Duty 

Heavy-Duty 

Operator

Operator

(For fast doors with high performance and speed managing requirements)

(For fast doors with high performance and speed managing requirements)

Rapido

 TM

RSH

RSH

READ AND FOLLOW ALL INSTRUCTIONS. 
SAVE THESE INSTRUCTIONS. 
GIVE TO END-USER.

Serial #                                                                  

Model #                                                                 

Wiring Diagram #                                                  

Project #/Name                                                     

Door #/Name                                                        

For technical support, please call 

1-800-361-2260

 or visit 

www.manaras.com

 for more information

FAS

TER

2X

Summary of Contents for Rapido RSH

Page 1: ...Heavy Duty Heavy Duty Operator Operator For fast doors with high performance and speed managing requirements For fast doors with high performance and speed managing requirements RapidoTM RSH RSH READ...

Page 2: ...Switch Functionality 5 2 3 Limit Switch Adjustment Using Manual Hand Chain 6 2 4 Low Voltage Controls and High Voltage Power Connections 7 2 5 Main Power Supply Connection 7 3 Electrical Drawings 8 3...

Page 3: ...Install the door operator at least 8 feet 2 44 m or more above the floor if the operator has exposed moving parts Covers or guarding provided by the manufacturer must be installed when the operator i...

Page 4: ...PUT SPEED 88 RPM NET WEIGHT Operator only 96 Lbs 44 Kg STANDARD WIRING TYPE C2 momentary contact to open stop and constant pressure to close APPLICATION Ultra high end heavy duty v belt drive for sect...

Page 5: ...usted accordingly to stop door in fully open position Close Limit Switch and Advanced Close Limit Switch Close Limits are not present on operators with an ECB In it s place the microprocessor has a bu...

Page 6: ...ges in the slots of both cams Advanced Close Limit 1 Using the hoist manually lower the door to approx 6 above the ground 2 Pull the cam retaining bracket from the Close side see Figure 2 and rotate C...

Page 7: ...panel as shown in Figure 3 2 Route all low voltage control wires as shown in Figure 3 KEEP LOW VOLTAGE WIRES SEPARATE FROM LINE VOLTAGE WIRES 3 USE COPPER CONDUCTORS ONLY 2 5 Main Power Supply Connec...

Page 8: ...8 3 Electrical Drawings 3 1 1 Phase 120VAC Rapido Operator and BOARD 070 For technical support please call 1 800 361 2260 or visit www manaras com for more information Figure 4 EDWG14070VFD03...

Page 9: ...9 3 2 1 Phase 240VAC Rapido Operators and BOARD 070 For technical support please call 1 800 361 2260 or visit www manaras com for more information Figure 5 EDWG14070VFD04...

Page 10: ...itten specifications are not properly applied by the Buyer when selecting the equipment If our written instructions for installation and wiring of the electrical connections have not been followed If...

Page 11: ...11 Notes For technical support please call 1 800 361 2260 or visit www manaras com for more information...

Page 12: ...Reg T M of 9141 0720 Qu bec Inc ADD1011 REV 8 2016 08 26...