24
7.3
Electronic Control Board (ECB) Programming
WARNING
To reduce risk of SEVERE INJURY or DEATH to persons:
•
Manaras-Opera strongly recommends the use of external entrapment protection devices, especially in
the case of momentary contact to close (B2 wiring or Timer to Close).
7.3.1
Run Mode Settings
NOTICE
•
Always return the door to
fully closed position
before performing any program settings.
C2 Mode
Selector switch
position on
0
SET SELECT SWITCH ON
C2 = 0
Function:
Momentary contact to
open and stop, constant-pressure-to-
close with 3-button station. Activation
of entrapment protection devices will
reverse the door while closing.
Auxiliary devices function as an Open
control and will reverse the door while
closing.
E2 Mode
Selector switch
position on
3
SET SELECT SWITCH ON
E2 = 3
Function:
Momentary contact to
open and constant pressure to Close.
Release of Close button or activation
of entrapment protection devices will
reverse the door to fully open
position.
B2 Mode
Selector switch
position on
1
SET SELECT SWITCH ON
B2 = 1
Function:
Momentary contact to
Open, Close and Stop with 3-button
station. Activation of entrapment
protection devices will reverse the
door during closing. Auxiliary devices
function as an Open-Close controls
and will reverse the door while
closing.
T Mode
Selector switch
position on
4
SET SELECT SWITCH ON
T = 4
Function:
Under Mode T=4, if
entrapment protection devices are
activated while door is closing, the
door will reverse and will not close by
Timer to Close (TTC). TTC will also
be disabled if the chain hoist is
engaged or if the stop is activated
before elapsed time. TTC will resume
its normal operation only after the
door is fully closed.
D1 Mode
Selector switch
position on
2
SET SELECT SWITCH ON
D1 = 2
Function:
Constant-pressure-to-
open and constant-pressure-to-close.
Activation of entrapment protection
devices will stop the door while
closing.
TS Mode
Selector switch
position on
5
SET SELECT SWITCH ON
TS = 5
Function:
Under Mode TS=5, if
entrapment protection devices are
activated while door is closing, the
door will reverse and will close by
Timer to Close (TTC). TTC will also
be refreshed if the chain hoist is
engaged, if the stop is activated
before elapsed time or in the case of
a power outage.
T (4) & TS (5) Mode: Only applicable with Timer to Close, refer to Features Programming section, p. 25.
For technical support, please call
1-800-361-2260
for more information