Man Roland IPS.LBA-1 Operating Instructions Manual Download Page 1

RIEE  B. 

Burk

hard

  12

/00

16.

869

02-0

029

 B / 

en

Operating Instructions - IPS.LBA-1

Operating Instructions

IPS.LBA-1

Summary of Contents for IPS.LBA-1

Page 1: ...RIEE B Burkhard 12 00 16 86902 0029 B en Operating Instructions IPS LBA 1 Operating Instructions IPS LBA 1 ...

Page 2: ...ification on the INTERBUS 2 1 4 2 General Technical Data 2 1 4 3 Technical Data of Remote Bus Interfaces 3 1 4 4 Technical Data of Loop Interface DT DT DR DR 3 1 4 5 Mechanical Data 3 1 5 Front View of Module 4 2 Block Diagram 5 3 Diagnostics LEDs 6 3 1 Subassemblies with Index A B 6 3 2 Subassemblies from Index D onwards 7 4 Pin Configuration 8 4 1 Connector Pin Assignment of X1 Remote In 8 4 2 C...

Page 3: ...y isolated but can be connected externally integrated mains unit for the I O subassemblies that are connected to the loop supplies 28 5 V DC Functions only in INTERBUS systems that are controlled by master firmware of Version G4 and above Diagnostics LEDs for the status of the INTERBUS and supply voltages No need to set DIL switches or jumpers ID code 4 04 hex Number of data words 0 MAN Item Numbe...

Page 4: ...ording to IEC 61000 4 2 ESD Class 3 assessment criterion 2 Immunity to interference according to IEC 61000 4 3 HF 10 V m assessment criterion 1 Immunity to interference according to IEC 61000 4 4 Burst Class 4 assessment criterion 2 Immunity to interference according to IEC 61000 4 5 Surge Class 2 assessment criterion 3 Immunity to interference according to IEC 61000 4 6 HF conductor 10 V assessme...

Page 5: ...h Maximum of 400 m Electrical isolation of the IN interface 500 V AC test voltage Data transfer Injected current signal to supply line three value Manchester coding Maximum line length between two loop nodes see al so Allgemeine Information Interbus Loop General Information on Interbus Loop Index A B 12 m Index D onwards 20 m but MAN ROLAND specification 12m Supply for loop subassemblies output fo...

Page 6: ...onnections Diagnosis LEDs Plug label for 24V supply for remote bus A B C D E F LOOP BUS ADAPTER Ident Number 4 Data Words 0 0V SL 0V L 24V SL 24V L Subassemblies labelling 5 6 7 8 9 10 DT DT DR DR U SL Out and LOOP 1 2 3 4 0V SL 0V L 24V SL 24V L 5 6 7 8 9 10 DT DT DR DR U SL U SL In U SL ERR LC Subassemblies with Index A B Subassemblies from Index D onwards Terminals for 24V supply and loop Termi...

Page 7: ...ating Instructions IPS LBA 1 2 Block Diagram Remote Remote In Out INTERBUS Controller SUPI Filter 5V 24V Logic Filter 28 5V 24V Current limitation 24V module supply 24V loop supply Loop OUT out Loop IN back Bridge not necessary from Index D onwards ...

Page 8: ...on is OK and the Interbus master is not resetting If the IN remote bus connection is disturbed the LED does not light up Bus Active green LED Shows cyclic data traffic across the Interbus signal lines Remote Bus Disable red LED The OUT remote bus interface is disabled Local Bus Loop Disable red LED The loop interface is disabled Error red LED The master can set this LED if it localizes an error on...

Page 9: ... yellow LED The loop interface is disabled Error red LED The master can set this LED if it localizes an error on the IPS LBA 1 or the I O modules that are connected to it UL RC BA RD LD E Incoming loop voltage terminals 5 and 6 green LED If the LED is not lit USLIN 15 5 V polarity is of no consequence Peripheral error message 0BB1hex is generated Outgoing loop voltage terminals 7 and 8 green LED I...

Page 10: ... two wire remote bus 4 2 Connector Pin Assignment of X2 Remote OUT 9 pin Sub D female connector for connecting the OUT two wire remote bus Pin Signal Meaning 1 DO1 Data out 2 DI1 Data in 3 GND Reference con ductor 4 5 6 DO1 Data out 7 DI1 Data in 8 9 Pin Signal Meaning 1 DO2 Data out 2 DI2 Data in 3 GND Reference con ductor 4 5 5V Logic voltage 6 DO2 Data out 7 DI2 Data in 8 9 RBST RBST signal ...

Page 11: ...10 is necessary to be able to detect a connected loop From subassemblies with Index D onwards this jumper is no longer necessary since in this case the system carries out electronic loop detection by monitoring the loop voltage Pin Signal Meaning 1 24VL 24V module electronics 2 0VL 0 V module electronics 3 24VSL 24V loop supply 4 0VSL 0 V loop supply Pin Signal Meaning 5 DT Data Transmit Data outw...